Lennox icomfort Wi-Fi Setup Manual page 39

Icomfort wi-fi thermostat
Hide thumbs Also See for icomfort Wi-Fi:
Table of Contents

Advertisement

Parameter Name:
AIR HANDLER
Equipment Name
Electric Heating Airflow
Low Cooling Airflow
High Cooling Airflow
Cooling Airflow Profile
Low Heating Airflow
High Heating Airflow
Continuous Indoor Blower Airflow
Humidification Airflow
Dehumidification Airflow
Delays:
Heating Indoor Blower OFF
Heating Indoor Blower ON
Cooling Indoor Blower OFF
Cooling Indoor Blower ON
HP Indoor Blower OFF
HP Indoor Blower ON
Table 3. Adjustable Parameters Table (Installer)
Default
Air Handler
nnnn CFM
NOTE: CFM Default and Values Settings are depen-
(See Note 3 at
dent on the tonnage of the unit
end of table)
1: No Delays,
2: ON: No delays; OFF: 45 sec delay
1
3: ON: 82%/7.5min; OFF: No delays
4: ON: 50%/30s,82%/7.5min; OFF:50%/30s
nnnn CFM
NOTE: CFM Default and Values Settings are depen-
(See Note 3 at
dent on the tonnage of the unit
end of table)
60 to 80% (percentage of reduction of High Cooling
70%
10 sec
0 sec
0 sec
2 sec
45 sec
0 sec
Page 39
Parameter Value Setting
(keyboard input screen)
Airflow)
0 to 10 Seconds
0 to 5 Seconds
0 to 30 Seconds
0 to 10 Seconds
0 to 60 Seconds
0 to 30 Seconds
icomfort Wi-Fit 7−Day Programmable Communicating Thermostat
Increment
Installer entry
5CFM
5CFM
5CFM
5CFM
5CFM
10CFM
10CFM
1%
1 sec
1 sec
2 sec
1 sec
5 sec
5 sec

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents