Lennox icomfort Wi-Fi Setup Manual page 40

Icomfort wi-fi thermostat
Hide thumbs Also See for icomfort Wi-Fi:
Table of Contents

Advertisement

Parameter Name
FURNACE
Heating indoor blower OFF delay
Heating indoor blower ON delay
Cooling indoor blower OFF delay
Cooling indoor Blower ON Delay
Heat pump indoor blower OFF delay
Heat pump indoor blower ON delay
Gas Heat Airflow Settings
Heating Airflow Control Type (variable
capacity furnaces only)
Low Heating Airflow (CFM @ min.
heat)
High Heating Airflow (CFM @ 100%
heat)
Low Heating Discharge Air
Temperature (DAT @ min heat)
(variable capacity furnaces only)
High Heating Discharge Air
Temperature (DAT @ 100% heat)
(variable capacity furnaces only)
* − Default DAT value is rounded to the closest number on 5 deg F resolution and limited by Minimum and Maximum value.
506920−01 09/12
Table 3. Adjustable Parameters Table (Installer)
Default
Min.
Max.
DIP SW
60
180
45 sec
15
45
0 sec
0
30
2 sec
0
10
45 sec
0
60
0 sec
0
30
0 – Fixed
0
1
CFM
DIP SW
DIP SW
See furnace docu-
mentation (IOM or
engineering hand-
DIP SW*
book) for size spe-
cific information
DIP SW*
Incr.
Dependency
10
None
5
None
2
Outdoor Unit
present
1
Outdoor Unit
present
5
Heat Pump present
5
Heat Pump present
1
DATS installed
25
Heating Airflow
Control Type = 0
25
5
Heating Airflow
Control Type = 1
5
Page 40
Note
Installer entry
DIP switch setting in
Non−comm.
45 sec fixed in Non−
Comm. IFC
Not used on Non
Comm. IFC
2 sec fixed in Non−
Comm. IFC
Not used on Non
Comm. IFC
Not used on Non
Comm. IFC
0 (Fixed CFM)
1 (Fixed DAT)
See furnace documen-
tation (IOM or engineer-
ing handbook) for size
specific information
table continued on next page