Configure Humidifier - Lennox icomfort Wi-Fi Setup Manual

Icomfort wi-fi thermostat
Hide thumbs Also See for icomfort Wi-Fi:
Table of Contents

Advertisement

Adjust a setting... Configure Humidifier (skip if no humidifier is being used or if humidifier is being used and default
Basic" humidification mode is desired)
System Devices
System
Air Conditioner
Furnace
Thermostat
Power (120VAC) Humidifier
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
Humidification Control Mode
Select one
Display Only
3a
Precision
Precision Dew Point
3b
save
To adjust a setting, highlight it,
then press Edit
System
1a
1b
Humidification Control Mode
current value:
back
Basic
2a
2b
System
Basic
1st Stage Differential
back
Basic Dew Point Control
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
Max Humidification Setpoint
cancel
OK/Humid Boundary
Outdoor Temperature Reading
9:39 am Aug 15, 2012
Figure 14. Adjust a non−communicating device setting HUMIDIFIER
Pre−adjustment REQUIREMENTS:
1st, the device has been installed (see Page 11).
2nd, you pressed next at the Add or Remove..." screen (see Page 11).
Configure the device as follows:
1. In the system devices" list, use the arrows (1a) to highlight System. Press edit (1b).
about
2. In the System" list, use the arrows (2a) to highlight Humidification Control Mode.
The current value defaults to Basic mode. Press edit (2b).
3. Touch one of the radio buttons (3a) to select the mode of humidification control;
edit
press save (3b). (After saving, check that the current value now shows the new
selection).
4. Use arrows (4a) to highlight any red colored text in the list (e.g. select Max Humidifi-
resetAll
cation Setpoint). Press edit (4b).
5. Use arrows (5a) to make changes; press save (5b). Repeat for other red settings.
You will not be able to advance to the next step until all red settings have been
next
removed..
6. Press the back button to return to Adjust a setting..." screen.
edit
NOTE − If the defaults for the settings shown in red, you are not required to make any changes,
but you must go into the edit tool, and press save (5b). When all red text is gone, the back button
will appear; press it to return to the Adjust a setting..." screen.
reset
Max Humidification Setpoint
current value:
45
4a
please view and save all
red settings
icomfort Wi-Fit 7−Day Programmable Communicating Thermostat
Page 15
Max Humidification Setpoint
Default is 45, inc:1
4b
edit
reset
5b
(returns to
back
adjust a
setting
screen)
Range is 15 to 45
set−to
5a
45
save
cancel