Table 5. Alert Codes and Troubleshooting
Alert
Priority
Alert Text
Code
418
Moderate
(Outdoor Unit) There is a faulty W" output cir-
cuit.
419
Critical
(Outdoor Unit) The W" output on the outdoor
unit has reported more than 5 errors. As a re-
sult, the system has shutdown the outdoor unit.
420
Critical
(Air Handler) The heat pump defrost cycle has
taken more than 20 minutes to complete.
421
Critical
(Outdoor Unit) The W" output terminal on the
outdoor unit is not wired correctly.
700
Moderate
(Stat) The temperature sensor in the thermostat
is not working properly.
701
Moderate
(Stat) The thermostat is reading indoor tempera-
tures above the pre−programmed limit.
702
Moderate
(Stat) The thermostat is reading indoor tempera-
tures below the pre−programmed limit.
703
Moderate
(Stat) The humidity sensor in the thermostat is
not working properly.
704
Moderate
(Stat) The thermostat is reading indoor humidity
levels above the pre−programmed limit.
705
Moderate
(Stat) The thermostat is reading indoor humidity
levels below the pre−programmed limit.
Ohm
The ohm reading in the system is either too
Check
high or too low.
Homeowner Service Alert Codes8
Number
Value
Number
3000
Filter 1
3002
3001
Filter 2
3003
506920−01 09/12
Value
Number
Value
Humidifier Pad
3004
Maintenance
UV Light
3005
PureAir Maintenance
Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer
alert button. Minor and Moderate alerts are found only in the Installer alert button.
Steps to clear
Faulty W output circuit.
W output hardware fault count reached 5 strikes.
Defrost cycle lasts longer than 20 minutes. Check heat pump operation. Cleared
when W1 signal is removed. Applicable only in communicating mode with non−communicating heat
pump.
Voltage sensed on W output terminal when Y1 out is deactivated.
Recalibrate thermostat to clear. Replace thermostat if needed.
Recalibrate thermostat to clear; cool thermostat; adjust setpoint. Replace thermostat, if needed.
Recalibrate thermostat to clear; warm thermostat; adjust setpoint. Replace thermostat, if needed.
Recalibrate thermostat to clear; adjust setpoint. Replace thermostat, if needed.
Recalibrate thermostat to clear. Replace thermostat, if needed.
Recalibrate thermostat to clear. Replace thermostat, if needed.
Ohm reading between i+ and i− anywhere on the RSBus with supply power off should be between 70
and 90 ohms. If above 90 ohms, check and repair wiring, splices or other wiring defects that may be
causing the excessive resistance. If less than 70 ohms, check for shorted wires.
Number
Value
4000
User WiFi state change, disable
4001
Firmware download failed
Page 54
Number
Value
4002
Image file download failed