Escape Sequences - AMX NXD-700i Operation/Reference Manual

7” modero wall/flush mount touch panel with intercom and table top touch panel
Table of Contents

Advertisement

^RAF, ^RMF - Embedded Codes (Cont.)
Parameter Embedded Code
refresh
newest
preserve

Escape Sequences

The ^RAF and ^RMF commands support the replacement of any special escape sequences in the filename
(specified by the %F embedded code) with the corresponding data obtained from the system as outlined in the
table below:
Escape Sequences
Sequence Panel Information
$DV
$SY
$IP
$HN
$MC
$ID
$PX
$PY
$ST
$AC
$AP
$CC
$CP
$LC
$LP
$BX
$BY
$BN
For instance, http://www.amx.com/img.asp?device=$DV
would become
http://www.amx.com/img.asp?device=10001.
NXD-700i & NXT-CA7 7" Modero Touch Panels
Description
The number of seconds between refreshes in which the resource is
'%R <refresh 1-65535>'
downloaded again. Refreshing a resource causes the button dis-
playing that resource to refresh also.
The default value is 0 (only download the resource once).
Set the newest file. A value of 1 means that only the most recent file
'%N <0-1>'
matching the pattern is downloaded.
The 'newest file' option only applies to FTP Dynamic Images, and
only those that have pattern matching as part of their filename.
Neither 'newest file' nor pattern matching apply to HTTP Dynamic
Images.
When set, the panel will first pull a list of files matching the given
pattern from the specified FTP server and path. The timestamps of
the items in the list will be compared, with the newest one being dis-
played on the panel. This is useful for source devices that place a
uniquely named still image in a folder at constant intervals, allowing
the panel always to display the most recent one.
Set the value of the preserve flag.
'%V <0-1>'
Default is 0. Currently preserve has no function.
Device Number
System Number
IP Address
Host Name
Mac Address
Neuron ID (Only supported on panels that use ICSNet; ignored on all other panels)
X resolution of current panel mode/file
Y resolution of current panel mode/file
Current state
Address code
Address port
Channel code
Channel port
Level code
Level port
X Resolution of Current button
Y Resolution of Current button
Name of Button
Programming
117

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxt-ca7

Table of Contents