Jst; Mbt; Mdc; Sho - AMX NXD-700i Operation/Reference Manual

7” modero wall/flush mount touch panel with intercom and table top touch panel
Table of Contents

Advertisement

Programming
"^" Button Commands (Cont.)

^JST

^MBT

^MDC

^SHO

96
Set text alignment using a numeric keypad layout for those buttons with a defined address
range. The alignment of 0 is followed by ',<left>,<top>'.
The left and top coordinates are relative to the upper left corner of the button.
Syntax:
"'^JST-<vt addr range>,<button states range>,<new text
alignment>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
new text alignment = Value of 1 - 9 corresponds to the following locations:
0
1
2
3
Zero can be used for an absolute position
4
6
5
7
8
9
Example:
SEND_COMMAND Panel,"'^JST-500.504&510.515,1&2,1'"
Sets the text alignment to the upper left corner for those buttons with variable text ranges
of 500-504 & 510-515.
Set the Mouse Button mode On for the virtual PC.
Syntax:
"'^MBT-<pass data>'"
Variable:
pass data:
0 = None
1 = Left
2 = Right
3 = Middle
Example:
SEND COMMAND Panel,"'^MBT-1'"
Sets the mouse button mode to 'Left Mouse Click'.
Turn On the 'Mouse double-click' feature for the virtual PC.
Syntax:
"'^MDC'"
Example:
SEND COMMAND Panel,"'^MDC'"
Sets the mouse double-click for use with the virtual PC.
Show or hide a button with a set variable text range.
Syntax:
"'^SHO-<vt addr range>,<command value>'"
Variable:
variable text address range = 1 - 4000.
command value = (0= hide, 1= show).
Example:
SEND_COMMAND Panel,"'^SHO-500.504&510.515,0'"
Hides buttons with variable text address range 500-504 & 510-515.
NXD-700i & NXT-CA7 7" Modero Touch Panels

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxt-ca7

Table of Contents