Corrective Maintenance; Power Source - Pace Sodrtek ST 125 Operation And Maintenance Manual

Analog desoldering system
Hide thumbs Also See for Sodrtek ST 125:
Table of Contents

Advertisement

a) Connect a 1 inch (2.5cm) length of clear pvc air hose to the FLOW OUT side of the
VisiFilter; push and turn the hose onto the VisiFilter nipple to seat.
b) Insert the ribbed end of a male quick connect hose mount fitting (P/N 1259-0087) into the
free end of the 1 inch (2.5cm) length of air hose connected to the FLOW OUT side of the
VisiFilter.
c) Connect the free end of the 137cm (54 inch) length of air hose to the FLOW IN side of
the VisiFilter.
d) Insert the end of the quick connect hose mount fitting (on VisiFilter FLOW OUT side) into
the power source Vacuum Port.
3. When using air pressure, and/or utilizing multiple air handpieces, PACE recommends the use
of the following set up procedure which utilizes additional quick connect hose mount fittings.
An assortment of quick connect air fittings are supplied with each additional air handpiece.
a) Disconnect the 137cm (54 inch) length of air hose from the FLOW IN side of the VisiFilter
assembly. Insert the ribbed end of a male quick connect hose mount fitting (P/N 1259-
0087) into the free end of this air hose.
b) Connect the free end of a 1 inch (2.5cm) length of air hose with an installed female quick
connect hose mount fitting (P/N 1259-0086) to the FLOW IN side of the VisiFilter
Assembly.
c) The 137cm (54 inch) length of air hose can now be easily moved between the VisiFilter
Assembly and the Controllable Pressure Port.
connected to the Vacuum Port.
4. Additional fittings may also be added to the hose connection at the rear of each air handpiece
to ease changing of handpieces.
NOTE: When removing any air hose, turn and pull. Do not attempt to pull hose directly off.
Damage to or breakage of fitting or VisiFilter may occur. Use your Sodr-X-Tractor with
a clean VisiFilter element. Otherwise a deterioration in performance or damage to the
unit may occur.

Corrective Maintenance

Power Source

Refer to the table below. Most malfunctions are simple and easy to correct.
Symptom
No power to
system
Handpiece will
not heat
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Probable Cause
Solution
Blown Fuse
Check handpiece using the appropriate handpiece
manual. Replace the fuse (located in the AC
Receptacle Fuse Holder) with one of the same
rated value.
Defective Heater
Refer to the appropriate handpiece manual
Power Source
Contact PACE
Malfunction
The VisiFilter assembly remains
Page 10 of 13