Temperature Adjustment Display Mode

The display will show the following when adjusting the desired Set Tip Temperature.
1. The Set Tip Temperature.
2. "HiL" (High Temperature Limit) when adjusting the set tip temperature and the
maximum allowable temperature is exceeded. Refer to the "Set-Up Mode" portion
of this manual.
3. "OFF" (Low Temperature Limit) when adjusting the set tip temperature and the
minimum allowable temperature is exceeded. Refer to the "Set-Up Mode" portion
of this manual.

Vacuum/Pressure Pump Operation

The PACE ST125 contains a vacuum pump that also provides air pressure. To activate, depress the activation button on
the connected handpiece. The ST125 has an optional foot pedal connector on the back, which can be used to activate
the pump instead of the switch on the handpiece.

Tip Offset

Differences between the temperature settings and true tip temperatures are negligible when using Thru-Hole,
single point soldering tips. With any heating system however, True Tip Temperatures can differ greatly from
temperature settings when using larger SMT soldering tips. Before adjusting offset, it is recommended to first
check the actual temperature of the tip using a Tip Temperature Monitor.
To adjust the temperature offset, hold the Program Key ( ) down for 5 seconds. The display will change to
show "000". If the unit already has a Tip Offset than it will be shown in place of "000". Use the keypad (
increase the temperature offset up to 83°C (150°F) hotter. When finished press the Program Key ( ) to return
to normal operation or, after 5 seconds of inactivity, the system will return to normal operation on its own

Default Factory Settings

Your new ST125 is equipped with several features which may be adjusted by the user. Listed below are the
factory settings of each. To learn about any of these features, refer to the applicable section of "Customizing
Your System" in this manual.
©2022 PACE Inc., Vass, North Carolina, All Rights Reserved
https://paceworldwide.com/
Feature
Password
Default Temperature Scale
(°C/°F)
"HI" Temperature Limit
"LO" Temperature Limit
SetBack Timer
Auto Off
Set Temperature
Tip Offset
Factory Setting
None Entered
°F for 115 VAC Systems
°C for 230 VAC Systems
427 °C (800 °F)
260 °C (500 °F)
Enabled, 30 minutes
Enabled, 60 minutes
371 °C (700 °F)
0 °C (0 °F)