Removing The Battery; Installing The Battery - HP xw4600 Service And Technical Reference Manual

Workstation
Hide thumbs Also See for xw4600:
Table of Contents

Advertisement

WARNING!
battery is handled improperly. Do not disassemble, crush, puncture, short external contacts, dispose in
water or fire, or expose it to temperatures higher than 60°C (140°F).
CAUTION:
are lost when the battery is removed. To back up the CMOS settings, select the Save to Diskette option
in the Computer Setup (F10) Utility.
NOTE:
Batteries, battery packs, and accumulators should not be disposed of together with general
household waste.

Removing the battery

To remove the battery:
1.
Disconnect power from the system
access panel
2.
On the system board, press the release tab of the battery holder.
3.
Rotate the battery just enough to get beyond the latch, and then lift it straight up.

Installing the battery

To install the battery:
1.
Confirm the polarity (positive or negative) of the battery to position it correctly in the battery holder.
2.
Place the battery edge under the plastic housing tab.
Figure 4-35
3.
Press down on the battery until the metal snaps engage.
88
Chapter 4 Removal and replacement procedures
This workstation includes a lithium battery. There is a risk of fire and chemical burn if the
Before removing the battery, ensure that the CMOS settings are backed up in case they
(Removing the side access panel on page
Removing the battery
(Predisassembly procedures on page
64).
58) and remove the side
ENWW

Hide quick links:

Advertisement

Table of Contents
loading