Serial Interface
Board, cont.
"uart3:"
Intermec EasyCoder 501 E – Installation & Operation Ed. 1
"uart3:" Serial Port
The communication port "uart3:" uses a DB-25pin male connector.
Pin
1
2
3
4
0
5
230V
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21–24
25
1
/. Enabled by a strap being fi tted on P-6.
2
/. DTR permanently high.
Refer to the installation instructions for the Serial Interface Board
for further information.
Signal Name
Description
GNDC
Cable Shield
TXD
RS-232 Transmitter
RXD
RS-232 Receiver
RTS
RS-232 Request To Send
CTS
RS-232 Clear To Send
DSR
RS-232 Data Set Ready
GNDI
Signal Ground
Not connected
+20M1
+20 mA current loop
-20M1
-20 mA current loop
+TXD
+TXD 20 mA current loop
-TXD
-TXD 20 mA current loop
+20M2
+20 mA current loop
(printer active receiver)
-20M2
-20 mA current loop
(printer active receiver)
Not connected
+5VEXT
5 VDC for external use (max. 200 mA)
Not connected
+RxD
+TXD 20 mA current loop
Not connected
DTR
RS-232 Data Terminal Ready
Not connected
-RxD
-TXD 20 mA current loop
Appendix 4 Interfaces