Page 1
DVI /VGA TO SDI SCAN CONVERTER OPERATOR’S MANUAL For the following models: MCP-601 for VGA and DVI graphics, analog and SDI video MCP-601-A for VGA and DVI graphics, and analog video MCP-601-D for VGA and DVI graphics, and digital SDI video...
Page 2
Copyright 2003, 2005 by Magni Systems, Inc. All rights reserved. No part of this publication may be reproduced in any form without written permission from Magni Systems, Inc. Printed in the U.S.A. Magni Systems, Inc. products are covered by U.S. and foreign patents, issued and pending.
Page 3
MCP-601 Operator’s Manual FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Page 4
MCP-601 Operator’s Manual Notes Magni Systems, Inc.
Installing the MCP-601 into a Rack..................21 Connecting the MCP-601 ......................22 Hardware Installation.......................22 Hardware Installation with Remote IR Controller only............22 Hardware Installation with Magni Premier application software and Remote IR Controller..24 Software Installation.........................24 Magni Premier Application Software ..................24 Setting up Control and Video I/O Configuration ..............24...
Page 6
5. BASIC OPERATIONS.......................38 Controlling the MCP-601......................38 Pan, Zoom, Underscan, VGA 1 to 1 and Mix Modes --- Magni Premier Mix Tab....38 Keying Operation and timing setup --- Magni Premier Key Tab ..........40 Adjusting the video squeeze size -- Magni Premier Size Tab ..........41 Saving and Recalling Memories Setting -- Magni Premier Config.
Page 7
MCP-601 Operator’s Manual Video sizing and Key lockout with the Size tab...............59 Video Squeeze: ........................59 VGA sizing, MagniPort and underscan modes ................60 Keying function ........................60 Key Type selection .........................61 Expanded Key color selection ....................61 8. FX-1 EFFECTS CONTROLLER....................62 FX-1 MagniCoder Pro FX Controller..................62 FX-1 Control Unit Buttons and Slider Bar................62...
Page 8
Command Format: ........................82 Command Codes: ........................82 Software developer Kit (SDK) ....................82 D. Firmware update........................83 Serial Communication Configuration: ..................83 Update MCP-601 Code using Hyper Terminal ................83 WARRANTY ..........................86 INDEX ............................87 Calibration Values (specific for this unit only) ................90 Magni Systems, Inc.
SDI graphics-to-video scan converter. The information presented will help to familiarize you with all aspects of the MCP-601 and provide a reference tool for questions you might have in the future. This guide is written specifically for anyone responsible for installing and operating the MCP-601.
Page 10
MCP-601 Operator’s Manual Chassis Grounding WARNING: The chassis is grounded through the ground conductor of the AC line cord. To prevent an electrical shock hazard, only plug the line cord into a properly grounded AC wall receptacle, as verified by a qualified technician.
IR remote controller, external FX-1 controller, Windows application software and custom control software. The MCP-601 encodes computer generated DVI displays directly to SDI-601, provides the highest quality video output currently available. The MCP-601 also combines DVI/VGA scan conversion capability with genlock and PC graphics overlay onto an incoming SDI 601 or analog (YUV, S-Video, or Composite) signal for applications such as titling, logo insertions, and adding computer-generated data to video.
Page 12
MCP-601and used to key the VGA display onto the video. The MCP-601 can be controlled by a hand-held IR remote controller, the Magni Premier application software through the RS-232 or USB ports, and the FX-1 controller unit. Resident software is not required on the computer to operate the unit.
MCP-601 Operator’s Manual Product Models MCP-601 Series come in three models. Each model comes in a configuration to suit a particular facility. MCP-601 has digital SDI-601 as well as analog Composite and Component video inputs and outputs. It is intended for digital/analog facilities and for those customers migrating to digital format.
Genlock allows synchronizing, mixing and overlaying DVI/VGA with SDI-601 and analog video Industry-proven genlock technology performs exceptionally well even with consumer-grade cameras and VCRs. The MCP-601’s genlock maintains low jitter when used with studio sources. Genlock to Reference Input or Internal Clock for scan conversion applications.
In addition, an optional Software Developer Kit (SDK) is available for 3rd party developers for custom software development. Remote Controllers You can also operate the MCP-601 (independent of the Magni Premier software) using an external FX-1 controller or IR remote controller. IR remote controller as the main controller...
MCP-601 Operator’s Manual Front Panel Description Figure 2-2. MCP-601 Front View The following components can be viewed from the front of the MCP-601. Indicators On when the LED lit: INPUTS: -VIDEO: Both Analog and SDI outputs are available simultaneously regardless of input.
16 17 Figure 2-3. MCP-601 Rear View The following cable connectors can be viewed from the rear of the MCP-601. Power entry connector and fuse holder (1 amp time delay/slow blow) with spare included. RS-232 input for control (9 pin Dsub).
INP UT MON ITOR BUF FERS OUT PUT Fig 3.1 MCP-601 Operational Block Diagram MCP-601 Block Diagram Descriptions Graphics Input (DVI or VGA) GRAPHICS INPUT SELECTION: The Graphics input can be selected from the analog VGA or the digital DVI inputs. The VGA analog input is digitized into a digital format.
A key color can be selected and compared to either the graphics or the video incoming signal. Whenever there is a color match, the mixer switches to output the other signal. This can be done in the MCP-601 internal mixer or through an external keyer, typically into an analog switcher with an external key input. For a digital switcher, the digital key signal from the MCP-601 is treated as another digital input signal.
Page 20
MCP-601 Operator’s Manual ALPHA KEY: One full frame of the graphics or the video signal can be stored in the Alpha Key memory. The Alpha Key can be set to act on the full picture as a pixel-by-pixel mix level between graphics and video.
4. INSTALLATION This chapter identifies the MCP-601 components that were shipped from the factory. This chapter also describes how to install the MCP-601, connect the MCP-601 to a computer, and how to install the Magni Premier application software. MCP-601 Components The following MCP-601 components were shipped from the factory.
The installation CD-ROM contains related information about the MCP-601. This information can help you get a better understanding of what the MCP-601 is and how you can use it to best fit your needs. Prior to loading any initialization files or the Magni Premier application software, we recommend that you look this information over.
Page 23
MCP-601 Operator’s Manual Operate the MCP-601 from the remote IR Controller. Use the MENU button to access the on-screen displays. Please refer to the sections on IR Controller and VIDEO OUTPUT ON-SCREEN DISPLAYS in this manual. For scan conversion or down stream keying application with external REF input as the...
Select My Computer Select CD-Rom drive, the Installation folder will appear. Select Setup.exe to install the Magni Premier program. Then follow the instructions to set up the program. NOTE: This MCP-601 operator’s manual is also available on the supplied User’s CD. Please refer to the Magni Premier Application Software section in this manual for more information.
Page 25
MCP-601 Operator’s Manual Figure 4-3, Config Tab on the Magni Premier Application Software Select Video Input: Factory startup, Analog SDI 601 Selects the serial digital input. Since the SDI signal has no color framing information, REF IN /CPST 2 can also be selected as the phase lock source for the analog Composite output.
(This will only take effect when the PowerUp save has been done.) Saving the settings (and all others) for power up: Make sure that you have the correct setting you need for power up of the MCP-601 and the Magni Premier Application software.
NOTE: If external key is not needed, or to avoid any input video mixed with the scan- converted output, turn the key off on the FX-1 or with the Magni Premier application software. This is true either controlled through the IR controller or Magni Premier application software.
MCP-601 Operator’s Manual Genlock Bandwidth Genlock filter mode selection also affects the output bandwidth of the incoming analog video signal. However, it has no effect on the SDI digital signal. There are three filter modes: Broadcast Relatively stable and full bandwidth studio signals For signal from VTR that have horizontal to subcarrier timing variations.
MCP-601 Operator’s Manual Typical Application and Genlock Settings Table 4-2, Recommended MCP-601 applications and genlock settings Default Video Genlock Chroma phase of Genlock Memory Application Input Source Composite analog output location Internal SC/H zero phase to the internal PowerUp Clock...
As long as there is no change in frequency no additional action is taken. When there is a change in sync frequency, the MCP-601 will react differently depending on whether the DVI or VGA input is selected. DVI input is the more precise since the signal contains all the needed data in the signal to determine the width, height and pixel clock of the image.
Pixel to pixel (Graphics to video) conversion mode -- VGA Zoom 1 to 1 On the Mix tab of the Magni Premier application software, the VGA Zoom 1 to 1 button enables a VGA (or DVI input) window of 720x480 in NTSC, and 720x576 for PAL, to be encoded to television video output.
Page 32
60 Hz, try a different refresh rate. For PAL, 720 x 576 is the One-to-One zoom area. --------------------------------------------------------------------------- NOTE: To access the debugging console: With the Magni Premier application software running, press [CTRL+C] will open the debug console --------------------------------------------------------------------------- Magni Systems, Inc.
A. Select USER 1: mode B. Input the data as in picture to the left. C. Set the priority to high so the MCP-601 will always use this mode. D. Press “Update User Display” button. E. On the IR Remote: Press the DVI button (Gets VGA out of lock); then Press the VGA button to relock to the VGA port.
A. Select USER 1: mode B. Input the data as in picture to the left. C. Set the priority to high so the MCP-601 will always use this mode. D. Press “Update User Display” button. E. On the IR Remote: Press the DVI button (Gets VGA out of lock); then Press the VGA button to relock to the VGA port.
MCP-601 Operator’s Manual Setting up Keying Configuration – Magni Premier Key Tab Figure 4-6, Magni Premier software Key tab screen Select the Key Edge Filter; Hard or Soft. Hard Key mode provides a sharp transition between graphics and video while Soft Key mode lengthens the transition time thus reducing motion artifacts in some cases.
H Filter Off provides sharpest picture on anti-alias and custom input graphics. Keying Filters (on the Key Tab of the Magni Premier software) affects the Key signal edges, thus affect the graphics/video transition edges:...
Increase range if possible for Full VGA or all other modes. -Config tab: Computer Input Filters: Horizontal, H Filter On Vertical, Reduced Flicker NOTE: Similarly, OEM customers can utilize the MCP-601 Commands and Control Codes (refer to Appendix C) to customize your applications. Magni Systems, Inc.
The MCP-601 has no front panel control facility except for the Power On/Off switch. However, the 14 LED indicators tells the operator the input and output status of the unit. The IR detector is located on the front panel of the unit for receiving signals from the IR remote controller.
Page 39
Autoset on some VGA cards.) When the program is running on a different display, the user can enter the graphics resolution of the VGA driving the MCP-601 by clicking on User Screen Size and entering VGA resolution.
MCP-601 Operator’s Manual Keying Operation and timing setup --- Magni Premier Key Tab Figure 5-2, Magni Premier software Key tab screen Key Edge Filter; Hard Key mode provides a sharp transition between graphics and video Soft Key mode lengthens the transition time thus reducing motion artifacts in some cases.
One SDI-601 digital key signal and one analog key signal are available for input to the switcher Adjusting the video squeeze size -- Magni Premier Size Tab Figure 5-3, Magni Premier software Size tab screen The settings under this tab allow controlling the video sizing (Video Squeeze) of the video input signal.
The Reset Lockout button removes all lockouts and resets video to full size. CAUTION: When the MCP-601 is in any of the Squeezed (or split screen) mode, adjusting the lockout area will automatically switch the video output to the Reset Video (or full screen) mode.
MCP-601 Operator’s Manual Factory Preset Default Memories (MCP-601) Table 5-1a VIDEO INPUT GRAPHICS Genlock VIDEO OUTPUT Factory Preset Default Memories FUNCTION Location Setting Resizer Input Resizer Source Format Type Color Graphics/Video Standard Scan Conversion: Internal Scan Conversion, VGA/ No input PowerUp Full scan SDI &...
Press any of the five input; SDI, CPST, CPNT, Y/C, and CPST2 will select it as the overlay video input source. Input select operates in an ON/OFF toggle mode. Press any input key once selects the input, press it the second time will turned that input off and the MCP-601 will then be in the Graphics Scan Conversion mode.
GRAPHICS section of IR Controller For Graphics input, select DVI or VGA, AUTOSET function automatically locks the MCP-601 to the VGA/DVI resolution of the computer. (The VGA Desktop color may need to be set to Blue when doing the Autoset for some VGA cards.) The graphics SIZE can be set to full size or underscan video output.
Page 48
MCP-601 Operator’s Manual Fig. 6-2 Preprogrammed VGA Magni Port (Selection from IR controller) NTSC 720 x 480 NTSC (1 to 1 mode) 720 x 480 (1 to 1 mode) SIZE 1. Upper left corner SIZE 2. Center 720 x 576...
Press CUT to switch between video and graphics as output. Press FADE to fade between video and graphics. Fade rate is set by software only (Magni Premier or command control codes). Freeze On, press FREEZE then press ON. Freeze Off, press FREEZE then press OFF.
Page 50
MCP-601 Operator’s Manual Fig. 6.3 Preprogrammed Video Squeeze sizes and their position (Selection from IR controller) ¼ of sides ¼ of sides (1) 6.25% of original, upper left corner (2) 6.25% of the original, center ½ of original sides ½ of original...
Page 51
The MENU button provides the setup functions of the unit, while the CAL button provides a means to calibrate the unit. Both MENU and CAL parameters are on-screen displays in the video output of the MCP-601. These parameters are listed on the Video Output On-screen Display section under the headings of MENU (For Setup) and CAL (Calibration of the unit).
Video Output On-Screen Displays MENU On-Screen Display The Menu operation can be accessed with the Magni IR remote controller or by pressing the MCP 601 IR button under the Config tab of the Magni Premier application software. To view the on –screen MENU display, set the mix level on the FX-1 Controller to 100% graphics so that only graphics is being displayed on the analog and SDI video outputs.
Page 53
¾ to ¼ weighting per data sample VGA ONLY: All analog VGA modes (USER, VGA, SVGA, XVGA, SXVGA, UXGA) AutoPos now: MCP-601 sets the position of graphic relative to the blue graphics size. AutoPos Enable: ON* enables auto positioning of VGA display when the unit recognizes there is a display changed.
MCP-601 Operator’s Manual Analog Input This is the analog input graphics conversion, or key and video overlay mode. SDI and analog outputs are always genlock to the selected analog input. Genlock Bandwidth: Select analog input bandwidth and genlock filter mode: Broadcast* Setup for full bandwidth studio video signals that are relatively stable.
Some gain adjustments may required test equipment. The following calibration function for the MCP-601 can be accessed through the CAL button on the IR remote controller or from the MCP 601 IR button in the Magni Premier application software.
Page 56
MCP-601 Operator’s Manual 5060 Graphics RGB Black Level RGB Contrast RGB Brightness RGB Black Level RGB Contrast RGB Brightness System VCO System VCO (frequency) Offset Print All Cal Consts (Calibration Constants) Store All Constants* * CAUTION: Do not store changed calibration values by initiating “Store All Constants” unless you are sure that every change is correct.
MCP-601 main unit. Although the MCP-601-IR remote controller can simultaneously control the MCP-601 main unit, the application software will regain control of the unit at the next refresh update. The software will perform a complete refresh update whenever there is an input video or input graphics changed, lost of either input, lost of genlock, or change of standards.
Memories can only be reset to factory default settings in two ways: 1) Through the Menu button on the remote IR controller or the MCP-601 IR button on the Config screen of the Magni Premier software (refer to the section on MCP-601 Video output on-screen displays), or 2) With the Command and Control Codes listed on page 29.
The four sides of the center rectangle (key enable area) are adjustable by dragging each side with the mouse pointer. Figure 7-4, Magni Premier Size tab screen Split screen video with graphics output under the Size tab through video sizing and lockout controls...
Figure 7-6, VGA Pan / sizing/ Underscan and Key control under the Mix tab of Magni Premier software Keying function Refer to Magni Premier Key tab in the Basic Operations section. Read Back button will display the Key color value that is being used.
MCP-601 Operator’s Manual Key Type selection Refer to Magni Premier Key Tab – Setting up Keying Configurations in Section 4. Installation. Figure 7-8, Key Type selection under the Key tab screen of the Magni Premier software Expanded Key color selection...
The FX-1 controller unit includes the FX-1 MagniCoder Pro control unit that contains the electronics to interface with the MCP-601 and the 8-pin phone wire cable. Connect the FX-1 control unit to the rear of the MCP-601 using the 8-pin phone wire. FX-1 MagniCoder Pro FX Controller Figure 8.1.
Page 63
Memory Pressing the bottom button lets you recall memory one to five. For more information on setting memory configurations, refer to section 6, “ IR Remote Controller” or 7, “Magni Premier Application Software”. Magni Systems, Inc.
9. APPLICATIONS Typical Applications and their Respective Settings There are many applications for the MCP-601 Series product. Scan Conversion, SDI video encoding, Downstream keying and internal keying and overlay are the more common ones. Following are three typical applications and the initial settings for each application:...
MCP-601 Operator’s Manual Typical Application’s Wiring Diagrams and Setups Video Overlay Fig. 9-1 Video Overlay with DVI Graphics and SDI-601 Video inputs Fig. 9-2 Video Overlay with DVI Graphics and Analog Video inputs Magni Systems, Inc.
Page 66
(2) MCP-601 provides two SDI outputs and one analog output simultaneously. The analog output can be in Composite, S-video or in Y, B-Y, and R-Y component format. (3) Video overlay described in Fig. 9-1 to 9-3 are for internal keying in the MCP-601. Magni Systems, Inc.
MCP-601 Operator’s Manual Alpha Key Video Overlay Fig. 9-4 Alpha Key Video Overlay with DVI or VGA Graphics and SDI 601 Video inputs Fig. 9-5 Alpha Key Video Overlay with DVI Graphics and Analog Video inputs Magni Systems, Inc.
MCP-601 Operator’s Manual Scan Conversions Fig. 9-6 Scan conversion of DVI Graphics input to SDI and analog video outputs Fig. 9-7 Scan conversion of VGA Graphics input to SDI and analog video outputs Magni Systems, Inc.
MCP-601 Operator’s Manual Scan Conversion with down-stream keying Fig. 9-8 Scan conversion of DVI Graphics to SDI video output with down-stream keying in external digital switcher. Fig. 9-9 Scan conversion of VGA Graphics to analog video output with down-stream keying in external analog switcher.
VGA card and SDI video input is digitally accurate. There is a potential offset between each VGA card’s analog RGB output and analog video input of the MCP-601. In both cases, it is advisable that Get Key is used to get the color and these numbers to be recorded for later re-entry.
The MCP-601 also has a MagniPort feature which is similar to Pan and Zoom that allows the user to define the area of the DVI / VGA display to be converted to video. The best resolution can be achieved through pixel-to-pixel encoding, that is by converting a 720 X 576 DVI / VGA display window to video in 625/50 PAL and a 720X480 display window to video in 525/60 NTSC.
Page 72
One can pick a certain location within the VGA screen and convert that portion of the image to full field video output. In the Magni Premier application software, go to the Mix tab, similar to the video squeeze procedure to set the MagniPort size and position. Memory functions also apply here.
MCP-601 Operator’s Manual 11. SPECIFICATIONS Electrical Computer Graphics Input for Scan Conversion Graphics Formats Digital Visual Interface (DVI) and Video Graphics Adapter (VGA) Graphics Input Switchable DVI Digital or RGB analog (VGA) One DVI-I female (Digital) connector One HD-15 female (VGA) connector with active loop through output...
(RS232, USB) , IR remote, FX-1 Controllers or Command Codes. Memory 11 settable memories including PowerUp setting for setup, Key, MagniPort, video sizing and control. Set and Recall by Magni Premier application software, IR remote, F/X Controller (1-5 only) and Command Control Codes. Magni Systems, Inc.
MCP-601 Operator’s Manual Keying Key modes Internal Key or External Key External Key has H and SC phasing adjustments. Key Type Graphics mixed with video in following forms: Color Black Key on graphics RGB component value set at 0 level.
MCP-601 Operator’s Manual Analog Video Output Composite Video Component Y, U, V or Y, B-Y, R-Y Luminance amplitude B-Y, R-Y (U,V) Color saturation Differential gain Sync (relative to -300 mV 5% -286 mV 5% (NTSC) blanking) -300 mV 5% (PAL)
Includes Installations software, Magni Premier Applicaion Software, Control Command Codes and MCP-601 Operator’s Manual. Part # 840-0301-xx Software Developer CD MCP-SDK-601 developer kit. MCP-601 SDK plus all items in the (Optional) Installation CD. Part # 840-0316-xx Cables DVI-D to DVI-D connecting cable (1). Part # 330-0116-00 HD-15P to DB-15P VGA cable (1).
MCP-601 Operator’s Manual Mechanical Rear Panel Connectors Power AC main connector 75 BNCs SDI-601 (1) and analog video CPST/Y; C/B-Y; R-Y (3) Video inputs Second Composite video input with loop thru output CPST2 (Composite 2) Genlock input (SDI input mode only) and passive loop through output...
The actual DVI connector in the instrument is a 29 pin DVI-I combined connector that includes the physical pins for the digital and analog signals. The MCP-601 only used the DIGITAL portion of the connector. Furthermore, only one digital channel is being connected. Pins 4,5,12,13,20 and 21 are for the second digital channel.
MCP-601 Operator’s Manual VGA Connectors (15-Pin Sub D) Description Description Description Ground Monitor ID bit 0 Green Ground Monitor ID bit 1 Blue Ground Horizontal sync Monitor ID bit 2 Not used Vertical sync Not used Ground Not used Figure A-2. VGA Pin Locations viewed directly at the rear panel...
However, DLL files are not necessary for the experience developer because the commands are simple text strings sent to an open port. The MCP-601 is shipped with RS323 communication rate set at 115K baud. (Settable via IR remote or Magni Premier Application Software).
3. Command definitions in Italics. 4. *(Value range of commands) Command Codes: For the list of commands and control codes, please refer to the file MCP-601 Control Command Codes on the supplied MagniCoder Premier MCP-601 Installation CD (Part No. 840-0301-00). Software developer Kit (SDK) Software developer Kit (SDK) and Command Codes are available on the optional CD ROM (Part No.
MCP-601 Operator’s Manual D. Firmware update The firmware of the MCP-601 can be updated to the most current codes by using a PC computer acting as a Hyper Terminal in conjunction with the Magni FX-1 Controller connected to the MCP-601. Follow the procedure that follows to update the codes.
Page 84
MCP-601 Operator’s Manual 5. At This point, Select the “Browse” button. 6. Then locate the appropriate file to send. 7. On completion of the file transfer the MCP601 will refresh the menu to allow for another file transfer. 8. Repeat set 2 to 7 for additional file transfer.
Page 85
MCP-601 Operator’s Manual 9. When the MCP601 powers backup again, type in on the terminal screen: (Configure to PAL Defaults) memory:default pal all (Configure to NTSC Defaults) memory:default ntsc all ONCE DONE, Close Hyper-Term. Magni Systems, Inc.
Magni does not warrant that the products will operate uninterrupted or error-free. Magni will not be liable for special, incidental, or consequential damages, including lost profits or loss of use or other economic loss. Magni's liability related to the products will in no case exceed an amount equal to the purchase price of the product giving rise to the liability.
MCP-601 Operator’s Manual Calibration Values (specific for this unit only) The factory calibration values printout sheet is attached on the following page(s). These values (cal constants) are unique to this particular unit. If for some reasons that your unit has gone out of calibration or becomes corrupted, you can restore the unit to its operational condition by entering these values with the supplied IR remote controller.