Standard Keypad Programming; Programming Using The Cf Switches - Hitachi SJ200 Series Instruction Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ200 Series:
Table of Contents

Advertisement

4–14
Using Intelligent Input Terminals
Option
Terminal
Code
Symbol
Valid for inputs:
Required settings:
Notes:
When programming the multi-speed settings, be
sure to press the Store key each time and then set
the next multi-speed setting. Note that when the key
is not pressed, no data will be set.
When a multi-speed setting more than 50Hz(60Hz)
is to be set, it is necessary to program the maximum
frequency A004 high enough to allow that speed.
While using the multi-speed capability, you can monitor the present frequency with
monitor function D001 during each segment of a multi-speed operation.
NOTE: When using the Multi-speed Select settings CF1 to CF4, do not display parame-
ter F001 or change the value of F001 while the inverter is in Run Mode (motor running).
If it is necessary to check the value of F001 during Run Mode, please monitor D001
instead of F001.
There are two ways to program the speeds into the registers A020 to A035:

1. Standard keypad programming:

a. Select each parameter A020 to A035.
b. Press the
c. Use the
d. Use the
2. Programming using the CF switches. Set the speed by following these steps:
a. Turn the Run command OFF (Stop Mode).
b. Turn inputs ON to select desired Multi-speed. Display the value of F001 on the
digital operator.
c. Set the desired output frequency by pressing the
d. Press the
indicates the output frequency of Multi-speed n.
e. Press the
frequency.
f. Repeat operations in 2. a) to 2. e) to set the frequency of other Multi-speeds. It
can be set also by parameters A020 to A035 in the first procedure 1. a) to 1. d).
Input
Function Name
State
C001, C002, C003, C004,
C005, C006
F001, A001 = 02,
A020 to A035
key to view the parameter value.
FUNC.
and
2
keys to edit the value.
1
key to save the data to memory.
STR
key once to store the set frequency. When this occurs, F001
STR
key once to confirm that the indication is the same as the set
FUNC.
Description
Example (some CF inputs require input
configuration; some are default inputs—see
page 3–41):
(MSB)
CF3
CF4
L
6
5
4
See I/O specs on page 4–6.
and
2
1
(LSB)
CF1
CF2
3
2
1
PCS
keys.