Example Wiring Diagram

The schematic diagram below provides a general example of logic connector wiring, in
addition to basic power and motor wiring covered in Chapter 2. The goal of this chapter
is to help you determine the proper connections for the various terminals shown below
for your specific application needs.
Breaker,
MCCB or GFI
Power source,
3-phase or
1-phase, per
inverter model
Intelligent inputs,
6 terminals
Forward
NOTE: For the wir-
ing of intelligent I/O
Reverse
and analog inputs, be
sure to use twisted
pair / shielded cable.
Attach the shield wire
for each signal to its
respective common
terminal at the
inverter end only.
Thermistor
GND for logic inputs
Meter
Analog reference
0–10VDC
GND for analog signals
R
(L1)
S
(L2)
T
N(L3)
PCS
1
Input
circuits
2
3
4
[6] configurable as
discrete input or
thermistor input
5
6
L
AM
H
O
4–20mA
OI
L
SJ200 Inverter
SJ200
U
(T1)
V
(T2)
W
(T3)
PD/+1
24V
+
PD/+
RB
Braking
resistor (optional)
N/–
AL1
AL0
AL2
Open collector outputs
Output
circuits
12
Freq. arrival signal
11
GND for logic outputs
CM2
4–5
Motor
DC reactor
(optional)
Braking
unit
(optional)
Relay contacts,
type 1 Form C
Run signal
Load
Load
+