Update (Firmware Update: 7500-7999) - Fujitsu XG2000 Series User Manual

Xg2000 series compact, 20-port 10 gigabit ethernet layer 2 switch
Hide thumbs Also See for XG2000 Series:
Table of Contents

Advertisement

XG2000 series User's Guide
Message ID
Severity
S7492
CRITICAL
S7493
CRITICAL
S7494
CRITICAL
S7495
CRITICAL
A.2.10

update (Firmware Update: 7500-7999)

Message ID
Severity
S7500
INFO
S7501
INFO
S7520
WARNING
S7521
WARNING
S7530
CRITICAL
A system-dump has been saved. Cause: machine check occurred (memory or bus data error).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the
note of the message content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred (bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the
note of the message content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred (memory or bus data error,
bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the
note of the message content before contacting the sales representative.
A system-dump has been saved. Cause: machine check occurred.
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the
note of the message content before contacting the sales representative.
init-firmup: New firmware '%1$' is running.
Explanation
New updated firmware was initialized.
[[Inserted string]]%1$: Firmware version information
init-firmup: Firmware '%1$' is running.
Explanation
New firmware was initialized after "boot" command was issued.
[[Inserted string]]%1$: Firmware version information
init-firmup: Booting new firmware failed. Old firmware '%1$' is now running.
Explanation
Old firmware was invoked because new updated firmware could not initialize.
[[Inserted string]]%1$: Firmware version information
Solution
Reattempt the update process to boot the new updated firmware.
If the message is repeatedly displayed, contact the sales representative.
init-firmup: Firmware update information is initialized for region %1$.
Explanation
The firmware information was initialized.
[[Inserted string]]%1$: Firmware number
Solution
No action is required if this message appears in Step 2 of
If the message is displayed every time the system is booted, contact the sales representative.
init-firmup: Internal error occurred (inconsistency in firmware update information).
Explanation
An error occurred while processing the firmware update information.
[[Inserted string]]%1$: Firmware version information
Solution
Note the message contents and contact the sales representative.
All Rights Reserved, Copyright (C) PFU LIMITED 2009
Message/Explanation/Solution
"tftp
put-maintenance" or
"tftp
put-maintenance" or
"tftp
put-maintenance" or
"tftp
put-maintenance" or
Message/Explanation/Solution
"Restoring Factory
295/315
"scp
put-maintenance" command then take
"scp
put-maintenance" command then take
"scp
put-maintenance" command then take
"scp
put-maintenance" command then take
Defaults".

Advertisement

Table of Contents
loading

Table of Contents