List Of Event Logs; Env (Health Monitoring: 0-999) - Fujitsu XG2000 Series User Manual

Xg2000 series compact, 20-port 10 gigabit ethernet layer 2 switch
Hide thumbs Also See for XG2000 Series:
Table of Contents

Advertisement

XG2000 series User's Guide
A.2

List of Event Logs

This section provides an explanation of message contents and actions to take for the associated message ID and severity in
ascending numerical order. There is no solution provided for messages that do not required action.
A.2.1

env (Health Monitoring: 0-999)

Message ID
Severity
S0101
ERROR
S0102
WARNING
S0104
WARNING
P0105
INFO
S0106
INFO
P0107
INFO
S0108
ERROR
%1$ Temperature is out of range. (%2$ %3$)
Explanation
The temperature is out range for normal operation.
[[Inserted string]]%1$: Location of detected temperature error.
Internal: The temperature inside the chassis
[[Inserted string]]%2$, %3$: Temperature value
Solution
Confirm the following checks on the device:
Check that the air vent is not blocked.
Check that the temperature of the switch environment is within the limits specified.
If there is no air vent blockage and the ambient temperature is within specifications, note the message contents
and contact the sales representative.
PWR-%1$ ALARM is detected.
Explanation
A power supply error was detected.
[[Inserted string]]%1$: Power supply unit number
Solution
Replace the power supply unit.
PWR-%1$ is Off Line.
Explanation
AC power is not reaching one of the power supply units.
[[Inserted string]]%1$: Power supply unit number
Solution
Check the AC cable and plugs.
PWR-%1$ is On Line.
Explanation
Power was restored to the power supply unit.
[[Inserted string]]%1$: Power supply unit number
PWR-%1$ is Removed.
Explanation
The power supply unit was removed.
[[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
PWR-%1$ is Inserted.
Explanation
A power supply unit was installed.
[[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
%1$ is out of range. (%2$)
Explanation
A supply voltage error was detected.
[[Inserted string]]%1$: Displays the types of power supply fault(s) (VDP/VDE/VDR/VDD/VDN/3.3V
Main/12V/3.3V(IF)/12V(IF)).
[[Inserted string]]%2$: Value that represents the power supply fault
Solution
Note the message contents and contact the sales representative.
All Rights Reserved, Copyright (C) PFU LIMITED 2009
Message/Explanation/Solution
281/315