lid assembly
lid gasket
lid handle
lid latch
manual shutoff valve
(gas fryers only)
P-H-T
pilot orifice
(gas fryers only)
pilot light
(gas fryers only)
poker brush
power/pump switch
pressure gauge
pressure pad
product
ready
safety relief valve
setpoint
shipping spacer
shortening mixing system
G-4
an assembly comprised of lid, lid handle, lid latch, and lid gasket (Note: on four
head fryers. the lid assembly includes spindles)
the gasket around the lid that creates a seal when the lid is properly latched
a handle that is attached to the lid and is used to lower the lid into contact with
the frypot; the handle is then pulled forward and pushed down to lock the lid in
place (see lid latch)
a mechanical catch on the front of the fryer lid that engages a bracket located on
the front of the frypot; the latch holds the lid down while it is being locked into
place
a valve located between the fryer and the wall that shuts off the flow of gas from
the supply line; this is not the main shutoff valve for the store
the automatic control of pressure, heat, and time to produce appealing food
product
a controlled opening for the pilot light located on the burner assembly
a small flame that remains burning even when the fryer is not in use; the flame
ignites the gas when the fryer is turned on
a brush that is included with the fryer that is used to clear the drain in the bottom
of the frypot. (also referred to as straight brush)
a three-way switch located on the front control panel of the fryer that serves as
an off/on switch and a filter switch
the gauge located on the left rear corner of the frypot that shows the pressure
inside the frypot
a piece of plastic on eight head fryers located between the lid locking arm and the
lid casting that helps create the seal for the lid; only a service technician should
perform maintenance or repair on the pressure pad
a food item cooked in the fryer
the starting, preset cooking temperature, at which product is placed in the
shortening
a spring loaded valve that automatically releases excess pressure if the operating
valve becomes obstructed; if the safety release valve activates, turn the Power/
Pump switch to "OFF" to release all pressure from the frypot
a preset cooking temperature; the setpoint is a programmable feature
a spacer located in the deadweight assembly for protection during shipment
an automatic system on eight head fryers that periodically uses the filter pump to
mix the shortening in the frypot to prevent an accumulation of moisture to
minimize the boiling action in the frypot