3-4. SWITCHES AND
INDICATORS (Continued)
HI Temperature Indicator
Drop Indicator
Done Indicator
Temperature Button
SCAN Button
FUNCTION Button
EXIT FILL Button
Multiple Timers
703
The display reads "HI" if the shortening temperature is 40° F above
the setpoint
The display reads "DROP" when the shortening has reached
the setpoint temperature (will read "DROP" 2° before setpoint and
4° above setpoint )
The display reads "DONE" at the end of the Cook Cycle
Allows the operator to read the temperature of the shortening while
in a Cook Cycle
Allows the operator to toggle through any running multiple timers
Used in the programming of the controls
After filtering the fryer, if in the Filter Lockout Mode, the display
reads "FILL" and the EXIT FILL button must be pressed
The control has the capability to run multiple timers; if more than
one product is being cooked, a timer can be started by pressing
more than one product button per Cook Cycle
The products must have the same setpoints, and the pressure
must be programmed off. See Programming Section.
Model PFE- 590/592