2-2. UNPACKING
INSTRUCTIONS
(Continued)
404
7.
Remove the counterweights from the pallet, which are
strapped to the pallet, under the fryer.
Do not drop. The counterweights weigh approximately
18 lbs. (8.1 kg.) each. Handle with care, or personal
injury could result.
8.
Remove rear service cover.
9.
Load the seven weights into the counterweight assembly. See
page 2-4.
10. Replace rear service cover.
To avoid personal injury and assure safe operation of
unit, rear service cover must be in place.
11.
Cut warning tags from the lid assembly. The lid may now
be unlatched.
12. Remove the accessories from inside the filter drain pan.
13. Prepare the deadweight valve for operation
The metal shipping support is placed within the deadweight
assembly housing to protect the deadweight orifice and dead-
weight during shipment. This support must be removed prior
to installation and start-up.
A.
Unscrew the deadweight cap.
B.
Remove the deadweight.
C.
Remove and discard the metal packing support.
D.
Clean the deadweight orifice with a dry cloth.
E.
Carefully place deadweight over deadweight orifice.
Replace deadweight cap, finger tight.
13.
Remove the protective paper from the fryer cabinet.
Clean exterior surface with a damp cloth.