Introduction

This section provides quick setup instructions to access the Web Browser through the RJ45
Ethernet interface. The Web user interface allows for complete monitoring and control of all
modem parameters and functions via a 10BaseT Ethernet connection. For more details on the
various WEB configurations and a description of all the available selections, please refer to the
manuals.
D.1

Required Items

Modem
RJ45 to RJ45 cable
Computer
Default Plug (J2)
The Web Browser menus for the OM20 can only be accessed utilizing
D.2

Web Interface Setup Guidelines

D.2.1 Preparing the OM-20 for Web Setup
The unit is shipped from the factory with specific IP defaults. The factory defaults are set to an
unreachable state to minimize any adverse effects to the user's network. In order for the user to
change the IP addresses to an accessible address the user must first install the Reset Plug onto
J2 that is supplied with the unit. This will change the IP network setting that the user can access.
1. Turn off power to the OM-20.
2. Install the Reset mating connector on J2 port.
3. Turn on power to the OM-20 and allow it to run for 2 minutes.
4. Turn off power to OM-20 and remover the Reset mating connector from J2.
5. The IP addresses of the OM-20 are now configured to the following:
Boot Modes:
Bootp Server Tag:
IP Address Mask:
Modem IP Address:
Server IP Address:
Router IP Address:
TM116 – Rev. 1.2
Microsoft Internet Explorer 6 or greater.
IPTEST
206
255.255.255.000
192.168.0.238
192.168.000.101
192.168.000.102