Radyne OM20 Installation And Operation Manual page 193

Universal outdoor modem
Hide thumbs Also See for OM20:
Table of Contents

Advertisement

OM20 Universal Outdoor Modem
Under Demodulator:
Under Demod IF:
Example 2:
Multidestinational Remote Site Programming
Drop 512 Kbps from a T1 trunk, 3/4 Rate Viterbi.
Extract 512 Kbps from a 1536 Kbps carrier and insert into a
T1 trunk, 3/4 Rate Viterbi.
Drop 512 Kbps from a T1 trunk, 3/4 Rate Viterbi
Extract 512 Kbps from a 1536 Kbps carrier and insert into a T1 trunk, 3/4 Rate
Viterbi
Under Interface:
Under RX Setup:
Set Rx Type according to your hardware configuration
Under Demodulator:
Under Demod Data:
Set Data Rate = 1536000
Set Conv Enc = 3/4 Rate VIT
Under Demodulator:
Set Network Spec. = Drop & Insert
Under Interface:
Under RX Setup:
Set Buff Size to desired depth
Under Rx D&I:
Set Insert Mode = T1-D4
Set T1 E1 Frm Src = External
Under Demodulator:
Under Demod IF:
Set Frequency to desired value.
TM116 – Rev. 1.2
Use SATCh TS edit capability to define proper mapping of
Satellite Channels to insert Terrestrial Slots
Use Map Copy to copy Rx Edit to Rx Active
Set Frequency to desired value
Configuration setup is exactly as previously shown in Example 1.
Use SATCh TS edit capability to define proper mapping of Satellite
Channels to insert Terrestrial Slots
For Satellite Channels that are not to be inserted, enter "NI" (No Insert)
for the Terrestrial Slot
Use Map Copy to copy Rx Edit to Rx Active
Appendix E
E-
11

Advertisement

Table of Contents
loading