Radyne OM20 Installation And Operation Manual page 92

Universal outdoor modem
Hide thumbs Also See for OM20:
Table of Contents

Advertisement

OM20 Universal Outdoor Modem
10 MHz BUC Reference:
Low Alarm Thrsh (Volts)
High Alarm Thrsh (Volts)
Low Alarm Thrsh (Amps)
High Alarm Thrsh (Amps)
BUC Voltage:
The following menus are for BUCs that support FSK command structure.
If user enables the FSK and the BUC does not support FSK, the modem
will display a fault or if the user selects the incorrect manufacturers BUC,
the unit will display a fault.
FSK COMMS
TM116 – Rev. 1.2
{ENABLED, DISABLED}
Allows the user to enable or disable the 10 MHz BUC
reference clock.
This menu allows the user to establish the lower voltage
threshold limit of the BUC. If voltage falls below this
limit, an alarm will flash.
This menu allows the user to establish the upper voltage
threshold limit of the BUC. If voltage exceeds the upper
limit, an alarm will flash.
This menu allows the user to establish the lower
Amp/current threshold limit of the BUC. If current falls
below this limit, an alarm will flash.
This menu allows the user to establish the upper
Amp/current threshold limit of the BUC. If current
exceeds the upper limit, an alarm will flash.
{ENABLED, DISABLED}
Allows the user to enable or disable the BUC supply
voltage.
{OFF-NONE/CODAN/TERRASAT/AMPLUS}
(Only available when the FSK Comm is Enabled)
OFF/NONE:
Will disable the FSK Communication link. User must
select this option if the BUC does not support FSK or if
the customer does not want to utilize the FSK option.
CODAN:
Enables the FSK Communication link for CODAN BUCs
only. This feature enables the DMD20LBST to retrieve
and display certain BUC parameters on the front panel
of the modem.
TERRASAT:
Enables the FSK communication link for Terrasat BUCs
only. This feature enables the DMD20LBST to retrieve
and display certain BUC parameters on the front panel
of the modem.
Web Browser/Remote Protocol