OM20 Universal Outdoor Modem
7.1.1.5 Drop and Insert Alarms
Alarm
Multiframe Lock
CRC Lock
T1 Signaling
E1 FAS (E1 Frame
Acquisition Sync)
E1 MFAS (E1 Multi-Frame
Acquisition Sync)
7.1.1.6 Common Major Alarms
Alarm
TERR FPGA CFG
CODEC FPGA CFG
+1.5V RX SUPPLY
+1.5V TX SUPPLY
+3.3V SUPPLY
+5V SUPPLY
+12V SUPPLY
+20V SUPPLY
TM116 – Rev. 1.2
The insert framer is not in sync.
An Insert CRC Fault occurred. Valid in T1-ESF, PCM-30, or PCM-
30C Modes.
An Insert T1 Yellow Fault occurred. Valid in T1-ESF, T1D4, or SCL-
96 Modes.
An E1 FAS Fault occurred. Valid in PCM-30, or PCM-30C, PCM-31,
or PCM-31C Modes.
An E1 MFAS Fault occurred. Valid in PCM-30, or PCM-30C, PCM-
31, or PCM-31C Modes.
Indicates an Interface Card FPGA configuration failure probably
caused by a missing, or wrong file.
Indicates Turbo Codec Card FPGA configuration failure probably
caused by a missing, or wrong file.
Displays the measured voltage of the 1.5 Volt Rx power bus located
inside the modem.
Displays the measured voltage of the 1.5 Volt Tx power bus located
inside the modem.
Displays the measured voltage of the +3.3 Volt power bus located
inside the modem.
Displays the measured voltage of the +5 Volt power bus located
inside the modem.
Displays the measured voltage of the +12 Volt power bus located
inside the modem.
Displays the measured voltage of the +20 Volt power bus located
inside the modem.
Maintenance and Troubleshooting
Possible Cause
Possible Cause
7-5