Installation Instructions; Clearances; Installation - Cannon CANTERBURY FREESTANDING User Instructions

Freestanding models
Table of Contents

Advertisement

10

Installation instructions

Overall dimensions:
1. This appliance is to be installed by a licensed service person only.
2. This appliance shall be installed in accordance with the manufacturer's
installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, and AS5601 the Australian Stand-
ard for gas installations. Refer also AS5601 for gas pipe sizing tables.
THIS HEATER IS NOT INTENDED FOR FIRE PLACE INSERT.

Clearances

3. Ensure the minimum clearances to combustible construction are main-
tained during installation, including adequate space for the proper op-
eration and servicing of the heater.
For clearances to curtains and furnishings refer to warning 3 & 4 on
page 4.
For minimum clearances refer fig 9 and 10.
9
4. Remove the carton from the heater and lift from pallet.
Check that the heater is suitable for the gas available. Refer to the data
label located on the fan chamber base, rear of pedestal front.
(Please dispose of packaging appropriately, keep away from children).
5. Prepare electrical and gas connections, a 10 Amp wall socket needs
to be located within 1.5m of the heater.
6. Fit rear spacers as per figure 10.

Installation

7. Place heater in position. (Check flue and gas connection positions.
Refer to gas connection instructions on page 11 and flue installation
instructions on pages 16 & 17, 18 & 19).
8. Remove the front glass surround by holding it firmly on either side and
pulling it towards yourself. Refer figure 11.
9. Remove the inner glass. Slacken off screws in top clamp and remove
side clamps. Refer figure 12.
Refer fig. 8.