1. This appliance is to be installed by a licensed service person
only.
2. This appliance is to be installed in accordance with the
manufacturer's installation instructions, AS 5601/AG601, Mu-
nicipal Building Codes, Electrical Wiring Regulations and any
other statutory regulations.
3. Remove the heater from the carton and remove the three transit
screws.
Check that the heater is suitable for gas available.
(Please dispose of packaging appropriately, keep away from
children).
4. Ensure the minimum clearances to combustible construction are
maintained during installation, including adequate space for
the proper operation and servicing of the heater. For clear-
ances to furniture and curtains refer to warning on page 4.
For minimum clearances refer figures 9 and 10.
Note: Ensure that the combustion air opening under the heater
is not obstructed.
9
A CLEARANCE OF 50mm MUST BE MAINTAINED BETWEEN
THE REAR OF THE CABINET AND THE REAR WALL OF THE
FIRE PLACE.
The clearance is required for correct fluing of the appliance. If
the clearance is less than 50mm a cabinet depth spacer must
be fitted. The spacer can be ordered from the relevant service
agent. Order specification for the spacer is 'Fitzspacer". To fit
the spacer follow the procedure described below.
a. Remove lower panel and front panel of heater as indicated
in figure 16 & 17.
b. Open the packaging and remove the three sections which
make up the spacer assembly. Refer figure 11.