8.
Sparks, ignites on low flame
then extinguishes after 10
seconds. Continues to spark
during flame presence.
9.
No gas to burner.
10.
Appliance lights but goes
into lockout.
11.
Fuse blowing.
31
• Check that the wall socket to the appliance has
correct polarity. Do not use an extension cord. Check
polarity in the electrical supply lead to appliance.
• Check that the sense electrode is in the flame.
• Check that appliance is earthed correctly. A check
between the earth pin on the plug and an unpainted
part of the appliance should see a resistance of
0.1 ohms.
• The gas valve should open at the same time as the
igniter sparks. If there is no gas to the burner when
this occurs check the solenoid coils for continuity.
• Check that the gas pressure is present at the test
point when the spark is being generated.
• Check that there is gas to the inlet of the gas control.
• Test the flame for correct ionisation signal. Connect a
multimeter in series with the flame rod and set the
function to measure micro-amps. The module will go
into lockout if the flame current sensitivity is less than
0.5 micro-amps. The approximate signal strength on
high flame is about 10 micro-amps and on low
4 micro-amps. The signal strength will fluctuate but
should be greater than 1.5 micro-amps at all times.
Take precaution because the ionisation probe can
have a high negative voltage and can cause shock.
• If the fuse continues to blow check the solenoid coils
for signs of them being shorted.
• Check the fan and wiring for short circuit.

Connections

Terminals 5, 6 and 7 at the module 12 way connector
are bridged.
Terminal 10 at the module 12 way connector is the ac-
tive supply via the red wire.
Terminal 11 at the module 12 way connector is the neu-
tral supply via the blue wire.
Terminal 12 at the module 12 way connector is the earth
connection via the green/yellow wire.
Terminal 12 at the module 2 way connector is the neutral
connection via a brown wire which is joined into the
rectifier cable then into the 8 way switch connector blue
wire.
Terminal 14 is an active connection at the module 2 way
connector via a white wire into the 8 way switch connec-
tor. This is active only when the flame is sensed.