fitzroy & Canterbury inbuilt installation instruCtions
Overview
1. This appliance MuST be installed by an authorised
service person only.
2. This appliance shall be installed in accordance with the
manufacturer's installation instructions, local gas fitting
regulations, municipal building codes, electrical wiring
regulations, and AS5601 the Australian Standard for
gas installations.
3. Open top of carton and remove accessories (logs).
lift carton up and remove. remove the four transit
screws fixing the heater to the pallet. Check that the
heater is suitable for the gas available. refer to the
data label located within the fan chamber (bottom
most area with fascia removed). (Please dispose of
packaging appropriately, keep away from children).
Installation Instructions
CANNON heaters MuST be flued with an appropriate
100mm diameter flue pipe. The reliance on the chimney
to provide effective flueing may result in poor combustion,
CO poisoning and possible death.
A solid, levelled and smooth base is required (fill gaps
with fibreglass insulation if necessary).
We recommend cleaning or sweeping the chimney and
fireplace before the installation of the heater commences.
There must be a good seal around the heater, gas piping
and electrical cable rear entry to stop any draught. Do not
use adhesives or silicone sealant, the heater must be able
to be easily removed if necessary.
Install a chimney plate and cowl to the chimney opening
using weatherproof mortar to common building practice.
Ensure there are no obstructions around cowl, i.e.
overhanging tree branches.
remove any curved fire wall that slopes too far forward
to the fireplace opening as it makes fitment of the flue
pipes difficult.
Make sure that the heater is fully commissioned and
be certain to conduct a test of the integrity of the flue
operation, taking into account any influences created
by range hoods, exhaust fans, central heating, etc.
refer to Australian Standard gas Installations AS 5601:
'commissioning'.
To avoid any unnecessary delays and inconvenience to
your customer please contact our Technical Services
Department on 1300 727 421 if the installation is unusual
or you have concerns with the installation and/or heater
operation before the installation commences.
refer to Australian Standard gas Installations AS 5601
for 'location of flue terminal'
Terminating a flue in a roof space is not permitted.
10 | Cannon Fitzroy / Canterbury Inbuilt
Any service requests resulting from incorrect
installations are not covered by our warranty
terms and conditions and these calls will result in
charges, usually to the end user, so please ensure
that the installation and commissioning has been
satisfactorily carried out before calling for any
warranty service.
Please make sure that your customer is fully instructed on
how to operate the heater.
Clearances
For minimum clearances refer FIG 5 and FIG 6.
A clearance of 25 mm minimum must be maintained
between the flue and flue spigot and any
combustible surface.
Ensure the minimum clearances to combustible
materials are maintained during installation, including
adequate space for the proper operation and servicing
of the heater. For clearances to furniture and curtains
refer to warning on page 5 (Safety Warnings).
Note: Ensure that the combustion air opening under the
heater is not obstructed.
Installation Into A Masonry/Brick Or Mock Fireplace
Both models FITZIB & CANTIB can be installed into a
masonry/brick fireplace or a mock fireplace. If installing
into a mock fireplace a mock fireplace installation kit
MuST be used. The mock fireplace kit can be ordered
from the CANNON distributor. Order specification for the
part is 'MOCKKIT12'.
Method of fixing to finished wall surface (plaster/
masonary/brick): suitable fixtures which are able to be
easily removed must be used
For installation into a masonry or brick fireplace with
a flue connection, refer FIG 7. After installation of the
heater, test the flue to confirm air vents are unobstructed.
If an exhaust fan or other heating/ventilation appliances
are present, switch them on. This is to test and ensure
that there is no interaction between the Cannon heater
and other appliances.
Refer to Australian Standard Gas Installations AS 5601:
For 'air movement not to affect appliance'
For 'air supply to appliance'.
For 'ventilation requirements'
Mock Fireplace Opening
(Combustible materials)*
Fitzroy Inbuilt
Max
Min
Height
640 mm
630 mm
Width
780 mm
731 mm
Depth
N/A
410 mm**
*If you have larger opening than the maximum height indicated, a surround kit is
recommended. **Includes 25mm clearance between flue spigot and rear wall
Canterbury Inbuilt
Max
Min
640 mm
630 mm
790 mm
731 mm
N/A
363 mm**