Do you have a question about the Canterbury and is the answer not in the manual?
Questions and answers
Marie
May 26, 2025
Under the plate that hides the wiring on the cannon Canterbury gas heater should there be a light glowing red and green at the bottom.We just had the heater serviced and each time he goes to put the bottom plate on the heater cuts out.
1 comments:
Mr. Anderson
May 26, 2025
Yes, the Cannon Canterbury gas heater has a green and red LED on the ignition controller. The green LED is on when the flame is sensed, and the red LED flashes according to fault codes. These LEDs are diagnostic aids located in the heater's wiring area.
Page 1
Inbuilt Heater Instruction Manual Please read this manual before installing and using this heater. Canterbury Fitzroy Please leave instruction manual with the owner Distributor This appliance is designed, manufactured and distributed by: Tel: 1300 727 421...
Practices act and similar laws of the States and territories. We warrant this Cannon appliance to be free of defects in materials, workmanship and manufacturing to the original purchaser for 2 years, (10 years on the heat exchanger) from the date of original purchase.
Do not use this fire if the glass is cracked or with heater on. the safety screen removed. Do not use fire with broken or missing logs. ON / OFF MEDIUM HIGH fig 1 fig 2 4 | Cannon Fitzroy / Canterbury Inbuilt...
Cannon’s appearance add a decorative 3 or 4 sided surround. every Cannon heater brings you the optional convenience of being controlled via a remote thermostat. For added convenience the heater can now be connected to a home automation system, such as C-bus.
Please note: • W hen installing into a mock fireplace a mock fireplace installation kit must be used. • T he data label is located in the fan chamber. Access by removing fascia. 808 mm 50 mm 347 mm 8 mm fig 3 front View and side View 6 | Cannon Fitzroy / Canterbury Inbuilt...
• W hen installing into a mock fireplace a mock 690 mm fireplace installation kit must be used. • T he data label is located in the fan chamber. Access by removing fascia. 850 mm 125 mm 298 mm 34 mm fig 4 front View and side View Cannon Fitzroy / Canterbury Inbuilt | 7...
Install a chimney plate and cowl to the chimney opening present, switch them on. this is to test and ensure that using weatherproof mortar to common building practice. there is no interaction between the Cannon heater and remove any curved fire wall that slopes too far forward other appliances.
Page 9
Depth 600 mm 520 mm** 550 mm 470 mm** *If you have larger opening than the maximum height indicated, a surround kit is recommended. **Includes 50mm clearance between flue spigot and rear wall Cannon Fitzroy / Canterbury Inbuilt | 9...
3. to remove the front heater surround undo two screws (one either side) from the bottom flange of the front panel as indicated in FIG 15. fig 12 fig 13 fig 14 grommet fig 15 fig 16 fig 17 Cannon Fitzroy / Canterbury Inbuilt | 11...
Sealing tape to be applied onto flanges of rear of front surround so as to seal against fireplace brick wall Sealing tape fig 19 fig 20 12 | Cannon Fitzroy / Canterbury Inbuilt...
Do not seal with a silicone sealant as the heater must be easily removable. Sealing is important as it prevents any leakage of flue products into the room. test all connections for gas leaks. Cannon Fitzroy / Canterbury Inbuilt | 13...
• Check that the gas pressure is correctly adjusted • Check that flue is operating correctly If the heater still does not operate to specification refer to the troubleshooting chart on page 19, or contact Sampford IXl in your state. adjust fig 31 14 | Cannon Fitzroy / Canterbury Inbuilt...
3. Disconnect the fan plug from the plug carrier. remove the two M5 wing nuts which locate the fan to the fan chamber underside. lower fan from male thread. gas & fan controller Ignition module gas valve fig 32 Cannon Fitzroy / Canterbury Inbuilt | 15...
Page 16
Spark gap between electrode and spark plate is 6 - 8 mm. Check for gas tightness. For log placement refer page 13 of this manual. To Replace Type “X”Cord Contact Sampford IXl service department. 16 | Cannon Fitzroy / Canterbury Inbuilt...
F3828 PURPLE BROWN ROOM FAN - F3594 1.5 AMP[18] EARTH BLUE BLUE IGNITION MODULE PRESSURE F3833 SWITCH F3327 240 V MAINS PLUG ROOM AIR FAN NATURALLY ASPIRATED WIRING DIAGRAM F3835 A fig 34 Cannon Fitzroy / Canterbury Inbuilt | 17...
Please refer to page 19 for a detailed trouble shooting table for Fitzroy and Canterbury Inbuilt heaters. Cannon Fitzroy and Canterbury Inbuilt there is a green and red leD on the ignition controller. these leDs act as diagnostic aids when the heater safety systems produce a safe shutdown condition.
Page 19
If there is no gas to the burner when this occurs check the solenoid coils for continuity. • C heck that the gas pressure is present at the test point when the spark is being generated. • Check that there is gas to the inlet of the gas control. Fuse blowing. • I f the fuse continues to blow check the solenoid coils for a signs of them being shorted. • Check the fan and wiring for short circuit. Cannon Fitzroy / Canterbury Inbuilt | 19...
Page 20
For service to this appliance or spare parts Gmk 10025 contact the CANNON distributor: Gmk 10030 AS4553:2008 Sampford IXL – Spare Parts Phone: 1300 727 421 Part number: Fax: 1300 727 425 F3841_A Email: aftersalesservice@sampfordixl.com.au 20 | Cannon Fitzroy / Canterbury Inbuilt...
Need help?
Do you have a question about the Canterbury and is the answer not in the manual?
Questions and answers
Under the plate that hides the wiring on the cannon Canterbury gas heater should there be a light glowing red and green at the bottom.We just had the heater serviced and each time he goes to put the bottom plate on the heater cuts out.
Yes, the Cannon Canterbury gas heater has a green and red LED on the ignition controller. The green LED is on when the flame is sensed, and the red LED flashes according to fault codes. These LEDs are diagnostic aids located in the heater's wiring area.
This answer is automatically generated