2.
Click Add. The Add RMON History Page opens:
Figure 134:Add RMON History Page
In addition to the RMON History Page, the Add RMON History Page contains the following fields:
Max No. of Samples to Keep — Defines the maximum number of samples that the device saves. The field
range is 1-65535. The default value is 50.
3.
Define the Source Interface, Owner, Max. No. of Samples to Keep, and Sampling Interval fields.
4.
Click Apply. The new entry is added to the history table, and the device is updated.
To edit an RMON history entry:
1.
Click Statistics > RMON History. The RMON History Page opens.
2.
Click Modify. The RMON History Configuration Page opens:
Figure 135:RMON History Configuration Page
3.
Define the fields.
4.
Click Apply. The new entry is added to the history table, and the device is updated.
Page 176
Viewing Statistics
Managing RMON Statistics

Advertisement