Step 3-A: Enable internal disk

When installing or reinstalling ESX to the internal disk, enable the settings of the internal disk by
using the BIOS setup utility. Follow the procedure below to enable the settings. (By default, the
settings of the internal disk are enabled. When it is not necessary to change the initial settings, go to
"Step 4: Invalidate OS Boot Monitoring Function".)
1.
Turn on the display and the peripheral equipment connected to the NEC Express5800/ft
series.
CHECK:
If the power cords are connected to a power controller like a UPS,
make sure that it is powered on.
2.
Detach the front bezel.
3.
Press the POWER switch that is located on the front side of the server.
IMPORTANT:
Do not turn off the power before the "NEC" logo appears.
After a while, the "NEC" logo will appear on the screen.
While the "NEC" logo is displayed on the screen, NEC Express5800/ft series is
performing the power-on self test (POST) to check itself. For details, see the
separate volume of User's Guide.
CHECK:
If the server finds errors during POST, it will interrupt POST and display the
error message. See the separate volume of User's Guide.
Front side of device
ESX Setup 4-7
CPU/IO module 0
CPU/IO module 1
Status LED
Power switch