<<< Check that synchronization has started with the specified RAID device name.>>>
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T0:L0
|_ vmhba100500:C0:T0:L0
mpm1 [2/2] resync=1.3% (930944/71484736) finish=13.8min (84631K/s)
|_ vmhba110500:C0:T1:L0
|_ vmhba100500:C0:T1:L0
<<< When synchronization is complete and the volume is fault-tolerant, the output appears as
follows >>>
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T0:L0
|_ vmhba100500:C0:T0:L0
mpm1 [2/2]
|_ vmhba110500:C0:T1:L0
|_ vmhba100500:C0:T1:L0
Status of RAID devices is the following for indications:
Status
resync
recover
check
repair
Meaning
It is in the process of recalculating RAID.
It is in the process of reconfiguring (resynchronizing) the devices that
are out of/illegal RAID configuration.
The disk is displayed as [ syncing ] while being reconfigured, and
[ in_sync ] after configuration is completed.
When it is done, [in_sync] is displayed.
It is in the process of checking data consistency.
It is in the process of checking/repairing data consistency.
[ in_sync ]
[ in_sync ]
[ in_sync ]
[ in_sync ]
[ in_sync ]
[ in_sync ]
[ in_sync ]
[ in_sync ]

Advertisement