Disk settings(RAID construction)
Use /opt/ft/sbin/mpmadm to construct RAID. Configure disks as follows:
IMPORTANT:
You must execute the following operations as root user.
Perform disk duplication by specifying and executing the RAID device name and the kernel device
name indicating the disk for mpmadm -C.
The following is an example of configuration of disks set in slot2 (10/40/2) and slot2 (11/40/3)
through creatiing
# cd /opt/ft/sbin/
<<< The disks loaded in the slot 2 of PCI module 0 and 1 are displayed in "Unused disks">>>
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T0:L0
|_ vmhba100500:C0:T0:L0
Unused disks:
- vmhba110500:C0:T1:L0
- vmhba100500:C0:T1:L0
<<< Perform disk duplication by specifying the RAID device name and the kernel device name indicating the
disk.>>>
# ./mpmadm -C mpm1 vmhba110500:C0:T1:L0 vmhba100500:C0:T1:L0
Successfully created volume mpm1.
Successfully assembled volume mpm1.
[ in_sync ]