4-40 ESX Setup
Configuring the redundant configuration, it is necessary to use "mpmadm" command.
On this occasion, the RAID device name is expressed as "mpmn" ("n" is 0 to 7).
IMPORTANT:
When the status of each disk becomes RESYNC, RECOVERY, CHECK or REPAIR, do not add
a disk, insert/remove HDD, power off or restart the system. Wait until the status indication of
Raid device disappears and the status of each disks become "in_sync". Check the status of
RAID using the "mpmadm" command, which is described later in this document.
Use only the hard disk drives specified by NEC. There is a risk of hard disk as well as the entire
device breakdown when you install a third-party hard disk drive.
Purchase two, paired hard disk drive of the same model to configure the hard drive redundancy.
For information on which HDD suits this device the best, ask your sales agent.
To confirm the disk status, use "/opt/ft/sbin/mpmadm –l" command.
The following display is an example when "/opt/ft/sbin/mpmadm –l" is executed.
# cd /opt/ft/sbin/
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T0:L0
|_ vmhba100500:C0:T0:L0
The internal disks path and device name
[ in_sync ]
[ in_sync ]