Use Of Internal Hard Disk Drives In The Raid System; Notes On Building Raid System - NEC EXP805 User Manual

Hide thumbs Also See for EXP805:
Table of Contents

Advertisement

Chapter 2 Preparations
1.32

Use of Internal Hard Disk Drives in the RAID System

This section describes how to use the internal hard disk drives in the RAID System.

Notes on Building RAID System

Note the following points when building a RAID System.
The number of hard disk drives required varies in each RAID level.
If the optional RAID Controller (N8103-189/195) is used, the RAID System cannot be built in
RAID5/RAID6/RAID50/RAID60.
In the RAID System, all the hard disk drives in a group (pack) must have the same capacity, interface type,
and rotational speed.
If you intend to install the OS to the RAID System, the process from RAID configuration to OS installation
can be easily completed by using EXPRESSBUILDER.
If you wish to install the OS manually, use RAID System Off-line Utility (Ctrl-R or HII). For details, see
Chapter 2 (2. RAID System Configuration) in "Maintenance Guide" or the manual supplied with the optional
RAID Controller (N8103-189/190/191/195/201)
182
Important
If you use hard disk drives in the RAID System or change the RAID level,
hard disk drives are initialized. If the hard disk drive contains valuable data,
be sure to backup the hard disk drive before installing the RAID Controller
and configuring the RAID System.
Note
Build a Disk Array in the RAID System using hard disk drives that have the same
specifications (capacity, rotational speed, and standard).
 Logical Drives can be created even with only one Physical Device.
Tips
 When using SAS hard disk drive, SAS SSD, it must be connected to RAID
Controller.
The minimum number of hard disk drives required to set up a RAID
RAID level
N8103-189/195
RAID 0
1
RAID 1
2
RAID 5
3
RAID 6
RAID 10
4
RAID 50
RAID 60
Important
Build a Disk Array in the RAID System using hard disk drives that have the
same specifications (capacity, rotational speed, and standard).
Express5800/R120h-2M (2nd-Gen) User's Guide
1. Installing Internal Optional Devices
System
N8103-190/191/201
1
2
3
4
4
6