5. Configuration Options

The D-Series Camera comes with defaults set (see Section 5.4: Default Settings). However, you
can make the following modifications to the FLIR D-Series Camera:
• Change the electronic wiring connections
• Change the dip switch settings on the PC board
To make the changes, you must first disassemble the Dome as described in
should be done by a certified CCTV person only.

5.1 Changing the Electronic Connections

The electronic connections may be changed on the electronic interface as shown below:
1
2
3
1. Welding point of coaxial cable
2. Fixing point of coaxial cable
3. RS485 Terminal (Left to right: B, A, GND)
4. 10-plug connector for ribbon cable
5. 24VAC Terminal (Left to right: AC24V, AC24V, SAFE-GND)
6. 24VAC (Spare use)
444-00001-00-10 Revision 110
Copyright © 2008 FLIR Systems, Inc.
Section
4. This
4
5
6
Page 23 of 33