4. Removing the main camera assembly from the housing
enclosure
With certain installations, including a pendant mount installation, it may be necessary to remove
the camera from the housing enclosure. It may also be necessary to remove the base from the
main camera assembly so the DIP switches are accessible (for example, to change the Pelco
address). The instructions for these disassembly steps are provided below.

4.1. Disassembling the Dome

The PC board and electrical interface board are located within the inner dome cylinder. To
disassemble the dome, follow these steps:
Step 1
If the power is on, power off the unit.
Step 2
Turn the trim ring counter-clockwise and remove it from the unit.
Trim ring
Step 3
Reach inside and lift the catch on the bottom of the inner cylinder. Push down on
the cylinder and turn the cylinder counter-clockwise to release it, then pull the
cylinder up.
444-00001-00-10 Revision 110