Power On Self-Test - FLIR D--Series Installation And Operation Manual

D series
Hide thumbs Also See for D--Series:
Table of Contents

Advertisement

The D-Series camera has grounding and surge protection to provide further immunity from high
current transients that can occur in installations that are subject to electrical storms and/or
nearby lightning events. In order to ensure CE and FCC compliance as well as to protect
against these high current events, installers are required to provide an earth connection to
the camera.
NOTE: A ground connection to the exterior of the camera (for example, to the spring clip) is
insufficient.
Caution! The camera must be installed according to industry-standard practices and local
electrical codes. Failure to properly connect the camera to ground could result in damage to
the camera and possible bodily injury.

3.2.1 Power On Self-Test

The D-Series Camera goes through a self-test process after power on. The camera will tilt up to
the top near the trim ring and the dome will perform a full rotation. The self-test is complete
when the camera tilts to the home position. Although the unit will produce a video signal
during the self-test, it is not possible to operate the camera (pan/tilt or other operations)
until the self-test process is complete.
NOTE: if you encounter problems with the self-check process, please refer to the
Troubleshooting section for recommendations.
444-00001-00-10 Revision 110
Copyright © 2008 FLIR Systems, Inc.
Page 11 of 33