Figure 5: Installation template (not to scale) ................14 Figure 6: Proper alignment of standoffs for installation of dome enclosure ........ 16 Figure 7: Ring installation (left); D-Series Dome camera installed in ceiling (right) ....16 Figure 8: PC board with DIP switch bank ..................24 Figure 9: Areas radiating heat appear brighter.
8. Do not install or operate the device in locations that contain flammable and/or explosive objects. 9. Do not try to repair the unit by yourself. FLIR Systems shall not be responsible for any problem caused by unauthorized amendment or repairing.
Congratulations! You have purchased one of the most important instruments you can have as part of your security system. The D-Series Thermal Camera is a state-of-the-art thermal imaging system especially suited to accommodate security surveillance of moving objects within a large area.
The D-Series Camera features a wide field of view and is capable of providing an image even in absolute darkness. Figure 1 shows the limitations of images obtained with a standard CCTV camera and the advantages provided by the D-Series camera in extreme conditions.
If there is any discrepancy between the list and the contents of your shipment, please contact FLIR Systems Customer Support immediately using the contact information at the front of this manual. Please retain the original shipping container and packing materials in case the camera possibly needs to be shipped in the future.
3. The installation materials must be capable of supporting well in excess of the weight of the product and accessories. FLIR Systems, Inc. is not responsible for damage or injury that results from an improperly installed camera.
3.2.1 Power On Self-Test The D-Series Camera goes through a self-test process after power on. The camera will tilt up to the top near the trim ring and the dome will perform a full rotation. The self-test is complete when the camera tilts to the home position.
3.3 D-Series Camera Connections Figure 4: D-Series Camera wiring connections WARNING: The Green/Yellow Ground wire must be properly connected in order for the camera to operate properly. 3.4 Drop Ceiling Installation (Typical Installation) WARNING! Make sure the Dome Camera and any other related equipment is powered off during installation.
5. Configuration Options The D-Series Camera comes with defaults set (see Section 5.4: Default Settings). However, you can make the following modifications to the FLIR D-Series Camera: ? Change the electronic wiring connections ? Change the dip switch settings on the PC board...
6. Using Your D-Series Camera 6.1. IR Imaging Views The D-Series Camera is easy to use, but you should take a moment to carefully read this section so you fully understand what you are seeing on your display. While the imagery you will see on the monitor may look like black and white daylight video, it isn’t! A few tips on how to...
Table 3: Troubleshooting Guidelines 7.1 Caring for your FLIR D-Series Camera For lens cleaning use the following materials: ? Optical-grade tissue (e.g., Edmund Industrial Optics part number 52105 or any similar product) ? Pure water (de-ionized or other)
8.2 Default Settings The FLIR D-Series Camera comes with a default address of 001 (Table 6), a baud rate of 9600, and default Pelco-D auxiliary command settings (Table 2). NOTE: If you decide to change the settings, FLIR recommends making the change before installation.
Need help?
Do you have a question about the D-Series and is the answer not in the manual?
Questions and answers