6.1 VQ 60 BI-AMP SYSTEM PARAMETERS

y
Parameter
Unit/Name
Gain
(dB)
Delay
(ms)
Polarity
Freq (Hz)
HPF *
Slope (dB/oct)
Filter Shape
Freq (Hz)
LPF
Slope (dB/oct)
Filter Shape
Freq (Hz)
Level (dB)
PEQ 1
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 2
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 3
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 4
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 5
Type
Q/Bandwidth
Electrical Transfer Function - Biamp VQ 60
10
0
-10
-20
-30
-40
10
100
Mid/High
Low (2x12")
PSW
0
-10
0.7
0
Positive
Positive
70
450
12
24
Butterworth
Linkwitz-Riley
500
out
48
Linkwitz-Riley
149
600
+4
+3
Parametric
Parametric
3.0/0.479
8.54/1.71
278
2100
-6
-2
Parametric
Parametric
2.4/0.597
5.04/0.286
1220
4600
-15
+4
Parametric
Parametric
5.04/0.286
2.0/0.714
6000
-3dB
Parametric
3.6/0.40
12000
+4
Parametric
5.04/0.286
1000
10000
Frequency (Hz)
LF
MF/HF
100000
9

Hide quick links: