3 way dual 12" large format loudspeaker for high performance installation applications, 2 way down-firing dual concentric mid-high loudspeaker for high performance installation applications, 2 way dual concentric mid-high large format loudspeaker for high (57 pages)
Passive column array loudspeaker with 15/30 drivers and fast dispersion, control for installation applications/en 54-24 certified, passive column array loudspeaker with 7 full range drivers and fast dispersion, control for installation applications en 54- (12 pages)
V300 is the natural choice. The 12” SuperDual™ ensures the most even frequency response over a wide coverage areain the medium size venues for which the Tannoy V300 is designed. In common with the rest of the V series products the V300 features a foam covered mesh grill, aesthetically essential for use in theatres and live performance applications.
Cable choice consists mainly of selecting the correct cross sectional area in relation to the cable length and the load impedance. A small cross sectional area would increase the cables series resistance, inducing power loss and response variations (damping factor). Connectors should be wired with a minimum of 2.5 sq.
V300 can be used in conjunction with the TDX2 or other OEM loudspeaker management systems.The Tannoy TDX2 Digital controller will provide crossover, parametric EQ, limiter and delay functions (See the relevant literature on the TDX2 for further information).
8. Arraying As discussed in the previous section, comb filtering is a phenomenon, which cannot not be cured by equalisation. Small alterations to loudspeaker positions can have the effect of minimising problematic combing frequencies. Arrays should be constructed so that the individual coverage patters of each loudspeaker combine with minimal overlap.
Tannoy Professional products, or any other devices. Using Tannoy Professional hardware for any purpose other than that indicated in this guide is considered to be improper use. Such use can be very dangerous as overloading, modifying, assembling in anyway other than that clearly stated in the manual, or damaging Tannoy Professional hardware will compromise safety.
V300 in both orientations to allow easy adjustment for optimum coverage. The vertical distance between the apex of the VMY and the top of the Tannoy V300 loudspeaker can be adjusted by connecting to varying mounting points on the bracket allowing varying degrees of vertical rotation.
Page 10
Fig 3. Number on Assembly View (Fig 3.) Description Quantity Hanging Bracket Cross Member Pivot Stud M10 Plain Washer M8 Spring Washer M10 Spring Washer M10 x 30mm Screw M8 x 20mm Screw M10 x 30mm Screw M10 Nyloc Nut Friction Washer 30mm Square Blank Plug Fig 4.
VMY, available in both black FIG 1. and white finishes, allowing the user secure the Tannoy V300 loudspeaker in either portrait or landscape orientations to a wall. The Tannoy V300 loudspeaker is attached to the bracket using the accessories supplied.
12.4 SECUR ET – VEB Eyebolt The Tannoy V300 loudspeaker can be flown with high quality VEB M10 eyebolts with collar to BS4278:1984. The loudspeakers are equipped with internal steel braces, which also double as the flying points, and accept VEB M10 eyebolts.
Fig 1. 12.7 SECUR – ET VPC Pole Clamp The VPC pole clamp can be used along with the VMY yoke bracket to suspend a Tannoy V300 loudspeaker from an overhead bar, truss or suitable structure. Only the parts supplied should be used to secure the VPC to the VMY yoke bracket.
13. System Configuration & OEM Controllers 13.1 Passive or Biamp? The V300 is supplied as standard for passive operation via the internal crossover network and is connected as shown in Figure 1. To reconfigure for Biamp operation simply follow the wiring schematic as shown in Figure 2.
13.2 Passive System Parameters (optional) With the vast array of digital loudspeaker management systems available it is inevitable that the user may opt to use a controller other than the TX2 & TDX2 as part of a large scale integrated system. In passive mode the V300 has been designed to need no external equalisation to overcome system limitations.
Work under warranty should only be carried out by a Tannoy Professional dealer or service agent. This warranty in no way affects your statutory rights. For further information please contact your dealer or distributor in your country. If you cannot locate your distributor please contact Customer Services, Tannoy Ltd at the address given below.