6.3 VQ 100 BI-AMP SYSTEM PARAMETERS

Parameter
Unit/Name
Gain
(dB)
Delay
(ms)
Polarity
Freq (Hz)
HPF *
Slope (dB/oct)
Filter Shape
Freq (Hz)
LPF
Slope (dB/oct)
Filter Shape
Freq (Hz)
Level (dB)
PEQ 1
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 2
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 3
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 4
Type
Q/Bandwidth
Freq (Hz)
Level (dB)
PEQ 5
Type
Q/Bandwidth
Electrical Transfer Function - Biamp VQ 100
10
0
-10
-20
-30
-40
10
100
y
Mid/High
Low (2x12")
PSW
0
-4
1.12
Positive
Positive
70
500
12
24
Butterworth
Linkwitz-Riley
500
out
24
Butterworth
149
3250
+4
-2.8
Parametric
Parametric
3.0/0.479
4.04/0.356
278
5200
-6
+4.4
Parametric
Parametric
2.4/0.597
5.43/0.265
450
6000
+3
-2.4
Parametric
Parametric
2.79/0.515
4.8/0.30
1220
9380
-15
+3
Parametric
Parametric
5.04/0.286
4.35/0.331
15000
-2.4
Parametric
5.84/0.247
1000
Frequency (Hz)
0
10000
100000
LF