13.2 Passive System Parameters (optional)

With the vast array of digital loudspeaker management systems available it is inevitable that the user
may opt to use a controller other than the TX2 & TDX2 as part of a large scale integrated system. In
passive mode the V300 has been designed to need no external equalisation to overcome system
limitations. If the V300 is to be used alone with additional bass enhancement required and have the
frequency response limits tighter than +/- 3dB as stated in section 11, then apply the parameters in
the table below for optimised performance:-
Parameter
Gain
Delay
Polarity
HPF â
LPF
PEQ 1 â â
PEQ 2
PEQ 3
PEQ 4
PEQ 5
â â
Note : When using the V300 with subs, set HPF @ 80 – 100Hz
(24dB/oct LR) and omit PEQ1.
PEQ 1 may also be omitted when using the V300 as a floor monitor.
Unit/Name
(dB)
User definable
(ms)
User definable
Positive
Freq (Hz)
45.1
Slope (dB/oct)
24
Filter Shape
Butterworth
Freq (Hz)
Thru
Slope (dB/oct)
NA
Filter Shape
NA
Freq (Hz)
60.1
Level (dB)
+7
Type
Parametric
Q / Bandwidth
2.8 / 0.3536
Freq (Hz)
281
Level (dB)
-2.5
Type
Parametric
Q / Bandwidth
2.0 / 0.500
Freq (Hz)
1560
Level (dB)
-2.5
Type
Parametric
Q / Bandwidth
4.8 / 0.2012
Freq (Hz)
3360
Level (dB)
-2
Type
Parametric
Q / Bandwidth
2.5 / 0.3969
Freq (Hz)
14800
Level (dB)
-3
Type
Parametric
Q / Bandwidth
4.0 / 0.2500