Tannoy VXP SERIES Operation Manual

Tannoy VXP SERIES Operation Manual

Vxp series professional loudspeakers
Hide thumbs Also See for VXP SERIES:

Advertisement

VXP SERIES
Professional loudspeakers
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VXP SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tannoy VXP SERIES

  • Page 1 VXP SERIES Professional loudspeakers Operation Manual...
  • Page 2: Important Safety Instructions

    AVERTISSEMENT DE SECURITE Le radiateur arrière de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au moins 5 minutes après la mise hors tension de l’appareil. VXP Series Operation Manual rev 1.0.2...
  • Page 3: Installation Instructions

    Neutrik ‘powerCON’ EEC directives issues by the commission of the European type NEC3FCA connector (Tannoy part number 3461 0919) community. Compliance with these directives implies conformity with the following European standards: as supplied with the equipment.
  • Page 4: Table Of Contents

    7. Arraying ..............................12 8. Dimensions ............................. 13 9. Rigging and Safety Procedures ......................18 10. Service Parts and Accessories ......................19 11. Technical Specifications ........................20 12. Warranty ..............................29 13. Declaration of Conformity ........................30 VXP Series Operation Manual rev 1.0.2...
  • Page 5: Introduction

    All VXP Series loudspeakers are designed to perform with very high efficiency and exceptionally low distortion, even when operating near peak output levels. At the heart of VXP Series is the latest genearation of Dual Concentric loudspeaker technology, which combines a high frequency driver and a low-mid driver on a common axis to create a true point source for all reproduced sounds.
  • Page 6: Unpacking And Visual Checks

    3.1 Preliminary Recommendation VXP Series loudspeakers can produce high sustained output levels for long periods of time. If users are in close proximity, these levels could lead to permanent hearing damage. Because Tannoy loudspeakers have a natural-sounding, flat frequency response and very low distortion, users may not be aware of the potential hazard.
  • Page 7: Rear Interface Panel

    ROCKER ROCKER POWER SWITCH - Supplies AC power on POWER SWITCH LEVEL CONTROL to the unit (100 V - 240 V) LED INDICATORS AC MAINS CONNECTOR - Neutrik powerCON mains connector (mating connector supplied) VXP Series Operation Manual rev 1.0.2...
  • Page 8: Operation

    THROUGH THROUGH HIGH PASS HIGH PASS LINE LEVEL LOOP LINE LEVEL LOOP MODE MODE THROUGH THROUGH LEFT LINE LEFT LINE VXP Series Operation Manual rev 1.0.2 LEVEL LEVEL OUTPUT OUTPUT LEFT LINE LEFT LINE LEVEL LEVEL OUTPUT OUTPUT POWER V...
  • Page 9: Ac Power Requirements

    • Reduce the output level of the mixer, or other source to the speaker. Signal LED – The Green LED indicates that a useable signal is present at the input. Power LED – StandBy - Red Active - Green Temp Prot. - Amber VXP Series Operation Manual rev 1.0.2...
  • Page 10: Audio Connections

    The limiting functions will protect the amplifier from long term overheating by attenuating voltage to the drive units. If used irresponsibly (constant hard clipping) sound quality will be compromised. In extreme cases drive units may also be damaged. VXP Series Operation Manual rev 1.0.2...
  • Page 11: Equalisation

    (Comb filtering creates an uneven frequency response across the coverage area due to constructive and destructive interference effects between the two sources.) Comb filtering cannot be cured by equalization; this should be addressed with proper arraying as discussed in the following section. VXP Series Operation Manual rev 1.0.2...
  • Page 12: Arraying

    The grille can be simply removed from this cabinet and be replaced for matching orientation. The grille is held in position by the two fixing screws on the top and bottom lips of the cabinet. VXP Series Operation Manual rev 1.0.2...
  • Page 13: Dimensions

    8. Dimensions 8. Dimensions VXP 6 225.0 215.0 [8.86"] [8.46"] 333.0 [13.11"] 115.0 75° 75° [4.53"] VXP 8 280.0 275.0 [11.02"] [10.83"] 388.0 [15.28"] 180.0 [7.09"] 135.0 [5.31"] 60° 60° VXP Series Operation Manual rev 1.0.2...
  • Page 14 8. Dimensions VXP 8.2 280.0 [11.02"] 590.0 [23.23"] 180.0 [7.09"] 145.0 60° 60° [5.71"] VXP 12 370.0 360.0 [14.57"] [14.17"] 180.0 406.0 486.0 [7.09"] [15.98"] [19.13"] 290.0 [11.42"] 180.0 [7.09"] 190.0 [7.48"] 60° 40° VXP Series Operation Manual rev 1.0.2...
  • Page 15 486.0 180.0 406.0 [19.13"] [7.09"] [15.98"] 290.0 [11.42"] 180.0 [7.09"] 190.0 [7.48"] 60° 40° VXP 12Q 370.0 360.0 [14.57"] [14.17"] 486.0 180.0 406.0 [19.13"] [7.09"] [15.98"] 290.0 [11.42"] 180.0 [7.09"] 190.0 [7.48"] 60° 40° VXP Series Operation Manual rev 1.0.2...
  • Page 16 780.0 [30.71"] 40.0 [1.57"] 290.0 [11.42"] 180.0 [7.09"] 190.0 60° 40° [7.48"] VXP 15HP 590.0 504.0 180.0 [23.23"] [19.84"] [7.09"] 43.0 450.0 200.0 [1.69"] [17.72"] [7.87"] 364.0 [14.33"] 180.0 [7.09"] 420.0 [16.54"] 200.0 [7.87"] VXP Series Operation Manual rev 1.0.2...
  • Page 17 8. Dimensions VXP 15Q 504.0 180.0 590.0 [19.84"] [7.09"] [23.23"] 450.0 43.0 200.0 [17.72"] [1.69"] [7.87"] 364.0 [14.33"] 180.0 [7.09"] 420.0 [16.54"] 200.0 [7.87"] 9. Dimensions VXP Series Operation Manual rev 1.0.2...
  • Page 18: Rigging And Safety Procedures

    Tannoy Professional hardware has been designed for use with specific Tannoy Professional loudspeakers, and is not designed or intended for use with any other Tannoy Professional products, or any other devices. Using Tannoy Professional hardware for any purpose other than that indicated in this guide is considered to be improper use.
  • Page 19: Service Parts And Accessories

    7900 1291 7900 1312 7900 1318 VXP 15HP 7900 1293 — 7900 0646 7900 1292 — 7900 1313 7900 1318 VXP 15Q 7900 1294 — 7900 0646 7900 1292 — 7900 1314 7900 1318 VXP Series Operation Manual rev 1.0.2...
  • Page 20: Technical Specifications

    A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 21 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 22 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 23 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 24 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 25 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 26 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 27 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification VXP Series Operation Manual rev 1.0.2...
  • Page 28 A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
  • Page 29: Warranty

    No maintenance of the VXP Series loudspeakers is necessary. All Tannoy VXP Series professional loudspeaker products are covered by a 5 year warranty* from the date of manufacture, subject to the absence of misuse, overload or accidental damage. Claims will not be considered if the serial number has been altered or removed.
  • Page 30: Declaration Of Conformity

    13. Declaration of Conformity 13. Declaration of Conformity The following apparatus is/are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate, Coatbridge, Scotland, ML5 4TF. The following equipment is marked with the CE label and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives.
  • Page 31 Notes Notes VXP Series Operation Manual rev 1.0.2...
  • Page 32 Tannoy adopts a policy of continuous improvement and product specification is subject to change. Dual Concentric, Integrip and Q-Centric Waveguide are trademarks of Tannoy Limited. IntelliDrive Energy Efficient Amplifier is a trademark of Lab.gruppen AB. All other trademarks remain the property of their respective owners.

Table of Contents