5.3.16 Sthreshold Control Signal Thresholds - Novatel EuroPak-15ab User Manual

Table of Contents

Advertisement

Commands

5.3.16 STHRESHOLD Control Signal Thresholds

This command controls signal acquisition and steady-state-lock signal thresholds. The sigchan, acqui, lock and
crosscorr fields must have values. They set the thresholds for the specified signal channel.
See also
on Page 122 for the mapping of signal channels.
Table 55
When you change this command, the selected channel loses lock and the locktime for its tracking satellite
is reset to zero.
Syntax:
STHRESHOLD
SIGCHAN
Field
Field
Name
1
header
2
sigchan
3
acqui
4
lock
5
crosscorr
a. The receiver does not have cross-correlation functionality at this point even though the command
requires a value.
Example:
STHRESHOLD 0 35 20 35
EuroPak-15ab Receiver User Manual Rev 1
ACQUI
Valid Values
This field contains the Abbreviated ASCII command name. See Section
4.1 on Page 34.
0-31
25-80
10-80
a
10-80
LOCK
CROSSCORR
Description
The parameters should be applied
to this signal channel.
Acquisition power threshold in
dBHz.
Steady-state tracking lock
threshold in dBHz.
Specifies the cross-correlation
power threshold in dBHz, at which
point, the checks are performed.
Chapter 5
Message ID: 803
Binary
Binary
Format
Bytes
Offset
H
0
Ulong
4
H+20
ULong
4
H
ULong
4
H+4
ULong
4
H+8
69