Logging Data; Log Types; Log Triggers; Log Triggers For Each Log Type - Novatel EuroPak-15ab User Manual

Table of Contents

Advertisement

Using Commands and Logs
4.2

Logging Data

You can control how the EuroPak-15ab logs data by using the LOG command given on Page 62. A field within
this command allows you to specify which data log from Chapter 6 to capture. Note the following however:
1. The EuroPak-15ab can handle 20 logs at a time. If you attempt to log more than 20 logs at a time,
the receiver will respond with the error message:
Not enough resources in system
2. Maximum flexibility for logging data is provided to you by these logs. You are cautioned,
however, to recognize that each log requested requires additional CPU time and memory buffer
space. Too many logs may result in lost data and degraded CPU performance. Receiver overload
can be monitored using the idle-time field and the buffer overrun bits of the Receiver Status field,
which are both found in any log header.
When a log is generated, it is sent to the serial port specified by the port parameter in the entered LOG
command.
4.2.1

Log Types

The receiver is capable of generating many different logs. These logs are divided into the following three types:
Synchronous
Asynchronous
Polled
4.2.2

Log Triggers

Each log can be configured for output when a certain condition, or trigger, is met. The possible triggers are:
ONNEW
ONCHANGED
ONTIME
ONCE
For each log type described in Section 4.2.1, Log Types only certain triggers are valid. For example, the
VERSION log is a polled log because it does not change. Therefore, it would not make sense to log this kind of
data using the ONCHANGED or ONNEW triggers. Table 5 outlines the valid triggers for each log type:
Synchronous
Asynchronous
EuroPak-15ab Receiver User Manual Rev 1
The data contained in synchronous logs is generated on a regular schedule.
The data in asynchronous logs is generated at irregular intervals. If these logs
were collected on a regular schedule, there would be a delay in capturing the
new data. The result is that changes to the data are not captured the moment
they were available.
The data in polled logs is generated only when requested. Typically the data
in these logs, such as configuration settings, does not change.
Output a new log whenever the message is updated (not necessarily changed).
Output a new log whenever the message has changed.
Output a new log at a specified interval (in seconds).
Output the current, existing message. Only a single log will be generated.
Table 5: Log Triggers for Each Log Type
Type
Recommended Triggers
ONCHANGED
Polled
ONTIME
ONCE
Illegal Triggers
ONNEW
ONCHANGED
-
ONNEW
ONCHANGED
Chapter 4
37

Advertisement

Table of Contents
loading

Table of Contents