NEC N8100-1078F User Manual page 83

Express5800/120eg
Table of Contents

Advertisement

Option
OS Watchdog
Timer Policy
Platform Event
Filtering
Temperature
Sensor
Post Error Pause
IMPORTANT:
Power Supply), select [Server] - [Resume on AC Power Loss] - [Power
On].
Parameter
Description
Always Reset
This option controls the policy upon PXE
[Retry 3 Times]
boot timeout.
If [Retry 3 times] is selected, the system
is reset after the occurrence of timeout
and OS boot is retried up to three times.
The failure in the third boot causes the
system reboot.
If [Always Reset] is selected, the system
is reset after the occurrence of timeout
and OS boot is retried repeatedly.
Disabled
Disables or enables triggers for system
[Enabled]
sensor events.
[Disabled]
Indicates whether the temperature
Enabled
sensor monitoring function is enabled or
disabled.
Disabled
Indicates whether POST is aborted once
[Enabled]
at the end of POST if an error occurs
during the execution of POST.
To power on the server from the UPS (Uninterruptible
Configuring Your Server 4-15
Your Setting
[
]: Factory-set

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8100-1079fExpress5800/120eg

Table of Contents