9-38 Upgrading Your Server
Removal
Remove the DIMM depending on the following procedure.
NOTES:
To remove the defected DIMM, check the error message appearing
in POST or NEC ESMPRO to identify the DIMM socket (group) in
which the defected DIMM is installed.
The server operates only when at least one DIMM is installed.
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Remove the side cover.
3.
Expand the levers at the both ends of the socket for the DIMM to be removed leftward or
rightward
The lock is released to allow the DIMM to be removed.
4.
Install the components removed in step 2.
5.
Turn on the power of the server. Then make sure that any error message does not appear
in POST.
If an error message appears, write down the message and review the error message list in
Chapter 8.
6.
Start the SETUP to select "Advanced" → "Memory Configuration" → "Memory Retest"
on the menus to clear the error information on the removed DIMM (see Chapter 4).