Scanning Documents; Configuring Ace Settings Before Scanning - Bell and Howell Copiscan 8000 Plus Series Operator's Manual

Hide thumbs Also See for Copiscan 8000 Plus Series:
Table of Contents

Advertisement

locations, plus the SERVICE position. The four positions are left of center, and can be
identified by subtle "stops" as the handle is moved from left to right. These "stops" line
up the imprinter print head with each print hole located in the scanner transport. The
imprinter prints through each print hole when lined appropriately.
CAUTION:
Check that the imprinter is positioned over one of the four holes in the scanner
transport prior to scanning documents.
To move the imprinter to the SERVICE position, slide the handle all the way to the left
until it stops. The ink cartridge should now be accessible from the left side.
CAUTION:
Do not close the scanner with the imprinter in the SERVICE position. The imprinter
may interfere with the side access door.
CAUTION:
Do not operate the scanner with the imprinter in the SERVICE position. Always
remove the ink cartridge and slide the imprinter to one of the four endorsing locations
when not in use.
5.5

Scanning Documents

When you scan a variety of document sizes and types, it's unlikely that all scanner runs
will require the same settings. Therefore, you may have to adjust scanner parameters, the
feeder, and/or the exit tray. This section integrates procedures for making and adjusting
those settings into the regular scanning routine. As you become more familiar with your
scanner and the types of documents that you will encounter, you will begin to intuitively
make the adjustments described here without interrupting your work flow.

5.5.1 Configuring ACE Settings Before Scanning

The scanner's ACE setting should be configured based on the type of documents you are
going to scan. This section contains the procedure to change the default setting and make
a test scan to assess if the new setting is appropriate. Remember, with time, this
procedure will become a habit, and your ability to choose a proper setting will become
easier.
Follow the procedure below to change the default setting and make a test scan:
1. Lift the skimmer assembly.
www.bellhowell.imagingcomponents.com
1-800-SCAN495
Copiscan 8000 Plus Series Operator Manual
54
August 25, 2000

Advertisement

Table of Contents
loading