3Ware 9650SE-2LPML User Manual page 28

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

Chapter 2. Getting Started with Your 3ware RAID Controller
18
"Configuring Your Controller" on page 80
"Setting Unit Policies" on page 106
"Setting Background Task Rate" on page 155
Initial Settings for Policies and Background Tasks
The table below lists the default settings for policies and background tasks.
These settings are used if you do not explicitly change the policy settings.
Table 6: Default Settings for Policies and Background Tasks
Policy
Controller-Level Settings
(For details, see "Configuring Your Controller" on page 80
Auto-Rebuild
Auto-Carving
Auto-Detect
Carve Size or Factor
Drives Per Spinup
Delay Between Spinup
Export Unconfigured (JBOD)
Disks
Staggered Method
Staggered Spinup
Unit-Level Settings
(For details, see "Setting Unit Policies" on page 106)
Auto Verify
Continue on Source Error
During Rebuild
Boot Volume Size
Queuing (NCQ)
StorSave Profile
Write Cache
Background Task Settings
(For details, see "Scheduling Background Tasks" on page 156 and "Setting
Background Task Rate" on page 155)
Default Value
Enabled
Disabled
Enabled
2048 GB
1
6 seconds
Disabled
ATA-6
Enabled
Disabled
Disabled
Blank
Enabled
Protection
Enabled
3ware Serial ATA RAID Controller User Guide
Where to Change
3BM, 3DM, CLI
3BM, 3DM, CLI
CLI
3BM, 3DM, CLI
3BM, CLI
3BM, CLI
3BM, CLI
3BM
3BM
3DM, CLI
3BM, 3DM, CLI
3BM
3BM, 3DM, CLI
3BM, 3DM, CLI
3BM, 3DM, CLI

Advertisement