A Battery Temperature Is Low; B Battery Temperature Is High - 3Ware 9650SE-2LPML User Manual

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

Chapter 12. Troubleshooting

004A Battery temperature is low

004B Battery temperature is high

256
Event Type
Warning
Cause
The battery pack temperature being monitored by the Battery Backup Unit
has fallen below the acceptable range. The most likely cause is ambient
temperature.
Action
The Battery backup Unit is presently still able to backup the 3ware RAID
controller, but you should replace the battery pack if the temperature warning
persists and is not due to environmental reasons.
Event Type
Error
Cause
The battery pack temperature being monitored by the Battery Backup Unit
has risen above the acceptable range. However, the BBU is still able to
backup the 3ware RAID controller.
Action
Check for sufficient airflow around the card. To increase airflow you can:
Leave the PCI slots next to the controller empty
Add fans to your computer case
Move and bundle wiring that is blocking air circulation
The Battery Backup Unit is presently still able to backup the 3ware RAID
controller, but you should replace the battery pack if the temperature warning
persists.
Contact 3ware technical support at
if this problem is not due to environmental reasons or improper case cooling.
http://www.3ware.com/support/index.asp
3ware Serial ATA RAID Controller User Guide