Performing a power-receptacle safety-check
For pluggable equipment, the socket-outlet shall be installed near the equipment
and shall be easily accessible.
"Portable power strip receptacles (temporary power taps)" on page xi, conforming
to all requirements, may be used.
A qualified electrician should perform all checks necessary to ensure safe
operation. These should include the following checks and any other required by
local regulations.
v Check the AC voltage at all associated power receptacles (see "4247 Model X03
v Check the AC impedance to ground at all associated power receptacles.
Attention: If the voltages are not within the correct operating range, allow
correction before the equipment is plugged in and operated.
4247 Model X03 nominal AC input power requirements
4
Quick Setup Guide
DANGER
<1-10> Hazardous voltages are present. Do not touch the pins or sockets of
the power receptacle.
nominal AC input power requirements").
Nominal Voltage
Voltage Range
100–240 Vac
Amps / Watts
90–264 Vac
3.8–1.6 A
Phase / Hz
Single phase /
50–60 Hz